Internal Resistance Calculator – EMF & r from Two Load Measurements
Use this free Internal Resistance Two-Load Calculator to find a battery's EMF and internal resistance from two simple measurements: the terminal voltage at two different load currents. This is the standard school-lab method — no need to short-circuit anything.
Every real source of EMF — battery, power supply, generator — behaves as though it hides a small resistor inside itself, in series with a perfect voltage source. That hidden resistor, the internal resistance r, is why a car battery that reads a cheerful 12.6 V on a multimeter can collapse to 9 V the moment the starter motor calls. It is also why "the battery is 12 volts" is only ever approximately true: the terminal voltage is the EMF minus whatever the internal resistance drops at the current being drawn, V = E − Ir.
Measuring r sounds awkward — you cannot open the battery and probe the resistor, because it is not a component; it is the sum of electrolyte resistance, electrode surfaces, connections and chemistry, distributed through the whole cell. The two-load method sidesteps the problem beautifully. Take two readings of terminal voltage at two different currents, and the pair of points pins down the straight line V = E − Ir: its slope is −r and its intercept is E. Two ordinary multimeter readings, no short circuits, no special instruments — the standard school-laboratory method, and the one this calculator automates.
The pair (E, r) is a battery's honest identity card. E tells you the chemistry's best effort; r tells you its health and its limits — the maximum current it can ever deliver (E/r, into a short circuit), the maximum power it can hand to any load (E²/4r, when the load matches r), and how cruelly its voltage will sag under your particular load. A rising r over months of two-load checks is the earliest reliable obituary a battery writes for itself.
Formula
Terminal voltage: V = E − I r • internal resistance from two loads: r = (V1 − V2) / (I2 − I1) • EMF: E = V1 + I1 × r = V2 + I2 × r (both forms must agree — a built-in check) • short-circuit current: Isc = E / r • maximum deliverable power: Pmax = E² / (4r), delivered when the load resistance equals r.
| Symbol | Meaning | Unit |
|---|---|---|
| E | EMF — the source's open-circuit (no-load) voltage | volt, V |
| r | internal resistance hidden inside the source | ohm, Ω |
| V1, V2 | terminal voltages measured at the two loads | volt, V |
| I1, I2 | the two load currents (must differ) | amp, A |
| V | terminal voltage at any current: V = E − Ir | volt, V |
The straight line hiding in your battery
Plot terminal voltage against current for any healthy source and the points fall on a straight line sliding downhill: V = E − Ir. Every feature of the line is a physical fact. The intercept, where the line meets the voltage axis at zero current, is the EMF — the voltage you measure with the load disconnected. The slope is the internal resistance wearing no disguise: lose 0.8 V when the current rises by 1.5 A and r is 0.53 Ω, whatever the battery is made of. And where the line meets the current axis — V fallen to zero — sits the short-circuit current, E/r, the most the source can ever deliver even into a dead short.
Two points define a line, which is precisely why the two-load method works and why one point cannot. A single (V, I) reading is consistent with infinitely many lines through it — a strong battery working hard or a weak battery working gently look identical from one point. The second reading, at a clearly different current, fixes the slope, and the whole identity of the source falls out. Choose the two loads far apart in current and the slope is measured accurately; choose them close together and small meter errors swell into large errors in r, because you are dividing by the small difference (I2 − I1).
Real sources bend the line slightly — chemistry polarises, resistance warms — so treat (E, r) as a snapshot valid near the measured currents and temperature, exactly as the original FAQ warns. For comparing batteries, tracking ageing, or predicting sag at a known load, the snapshot is everything you need.
How to use
- Connect a light load to the source. Record the terminal voltage V1 and the current I1 while that load is connected.
- Change to a clearly heavier load (a current at least twice the first, ideally more) and record V2 and I2.
- Enter all four values and click "Calculate" for r and E.
- Check the result both ways: E should equal V1 + I1·r and V2 + I2·r. Then use V = E − Ir to predict the terminal voltage at any other current.
- Take the two readings promptly, at the same temperature and state of charge, so the snapshot is self-consistent.
Worked examples
Example 1 — the standard measurement. A battery shows V1 = 11.6 V while supplying I1 = 0.5 A, and V2 = 10.8 V while supplying I2 = 2 A.
r = (11.6 − 10.8) / (2 − 0.5) = 0.8 / 1.5 = 0.53 Ω.
E = 11.6 + 0.5 × 0.53 = 11.87 V.
Check with the second reading: 10.8 + 2 × 0.53 = 11.87 V — the same EMF, as it should be.
Example 2 — a fresh AA cell. A new AA cell reads 1.45 V at 0.1 A and 1.25 V at 0.5 A. r = (1.45 − 1.25)/(0.5 − 0.1) = 0.2/0.4 = 0.50 Ω; E = 1.45 + 0.1 × 0.5 = 1.50 V — the familiar nominal voltage of the chemistry, recovered from two loaded readings even though neither reading itself showed 1.50 V.
Example 3 — a car battery under cranking-class loads. Terminal voltage 12.2 V at 5 A (lights and blower) and 11.0 V at 50 A (a heavy test load). r = (12.2 − 11.0)/(50 − 5) = 1.2/45 = 0.027 Ω; E = 12.2 + 5 × 0.0267 = 12.33 V. The theoretical short-circuit current is E/r = 462.5 A — the right order of magnitude for the several-hundred-amp cranking currents these batteries are built to deliver, and a fine r for a healthy unit.
Example 4 — the tired 9 V battery. An old 9 V battery reads 8.6 V at 50 mA but sags to 6.9 V at 0.3 A. r = (8.6 − 6.9)/(0.3 − 0.05) = 1.7/0.25 = 6.8 Ω; E = 8.6 + 0.05 × 6.8 = 8.94 V. The EMF looks nearly respectable — yet with r twenty times a fresh cell's, this battery will fail in any demanding device. This is the measurement that explains "the battery tested fine but the gadget still dies."
Example 5 — predicting limits from Example 1. With E = 11.87 V and r = 0.53 Ω: short-circuit current Isc = E/r = 22.25 A (never test this directly — the two-load method exists precisely to avoid it). Maximum power transfer: Pmax = E²/(4r) = 11.87²/(4 × 0.5333) = 66.01 W, delivered to a 0.53 Ω load at 11.12 A with the terminal voltage fallen to E/2 — impressive power, terrible efficiency, which is why real systems never run matched.
Example 6 — a USB power bank. Output measures 5.05 V at 0.2 A and 4.75 V at 1.5 A. r = (5.05 − 4.75)/(1.5 − 0.2) = 0.3/1.3 = 0.23 Ω; E = 5.05 + 0.2 × 0.2308 = 5.10 V. At a 2.4 A phone-charging draw the output would sag to V = 5.10 − 2.4 × 0.23 = 4.54 V — below the USB comfort zone, predicting the slow-charge complaint before the phone is even plugged in.
Internal resistance in real life
- Battery health testing: workshops and battery-management systems track r over time; a doubled r is the standard retirement criterion, long before capacity tests finish.
- Cold-morning failures: electrolyte resistance climbs steeply in the cold, so r measured on a frosty morning explains why a "summer-fine" battery cannot crank.
- UPS and solar sizing: predicted sag V = E − Ir at inverter surge currents decides whether a battery bank holds voltage or trips the inverter.
- Power-supply design: a bench supply's load regulation is exactly its effective internal resistance — milliohms for a good regulated unit.
- Phone and EV engineering: voltage sag under pulse loads limits camera flashes, transmitters and acceleration; low-r cells command premium prices for this reason.
- School laboratories: the two-load experiment remains the standard practical because it teaches slope, intercept and honest measurement in one tidy line.
Maximum power transfer — and why engineers avoid it
The (E, r) pair answers a famous question: what load extracts the most power from a given source? Calculus (or completing the square) gives R = r, at which Pmax = E²/(4r) — Example 5's 66.01 W. But at that operating point the terminal voltage has fallen to E/2 and exactly half the total power heats the source itself: efficiency is 50%. Power engineers therefore run sources heavily unmatched — loads many times r — keeping efficiency high and sag small, and treat Pmax as a ceiling of physics, not a target. Audio and RF engineers, chasing signal rather than efficiency, do match deliberately. Knowing which game you are playing starts with knowing r — which is to say, with the two-load measurement on this page.
Quick reference: from two readings to r
| ΔV between readings | ΔI between readings | r = ΔV/ΔI |
|---|---|---|
| 0.8 V | 1.5 A | 0.53 Ω |
| 0.2 V | 0.4 A | 0.50 Ω |
| 1.2 V | 45 A | 0.027 Ω |
| 0.3 V | 1.3 A | 0.23 Ω |
| 1.7 V | 0.25 A | 6.8 Ω |
Rule of thumb: the bigger the current swing between your two loads, the more trustworthy the slope. Aim for ΔI at least half the largest current you care about.
Internal resistance across chemistries, cold and age
The two-load snapshot becomes far more useful with reference points. A fresh AA alkaline cell measures around 0.15–0.3 Ω by this DC method when new, climbing past 1 Ω as it empties; Example 2's 0.50 Ω is a mid-life cell. A healthy car battery lives in the milliohms — Example 3's 0.027 Ω is typical — because its plates offer enormous area. Lithium-ion cells sit between: a single 18650 commonly measures 0.05–0.1 Ω, which is why a ten-cell pack's sag is dominated by cell count and interconnects as much as by chemistry. Supercapacitors boast milliohm-class resistance, one reason they deliver such violent currents.
Temperature rewrites all of these numbers. Electrolyte conductivity falls steeply in the cold, and a car battery's r can roughly double between a warm afternoon and a hard frost — the same battery, the same charge, half the cranking courage. State of charge matters too: a lead-acid battery's r rises as it discharges and sulphates, while a lithium cell's r climbs sharply at very low charge. Finally, a subtlety for the careful: manufacturers often quote AC impedance at 1 kHz, which reads lower than the DC two-load value because it skips slow chemical polarisation. Compare like with like — DC method against DC history — and your two-load log becomes a genuine health record rather than a pair of disconnected numbers.
The third reading: catching a bent line
Two points define the line, but a third point audits it. Take a third reading at an intermediate current and check whether it sits on the line your first two points drew — predicting its voltage from V = E − Ir and comparing. Agreement within meter tolerance certifies the snapshot; a point sagging noticeably below the line betrays polarisation or heating during the heavy test (the battery tired mid-measurement), while a point above the line suggests the source was charging or recovering between readings. Laboratories formalise this as a load sweep, but the principle fits on a bench: two points for the answer, one more for the truth. When the third point bends, retake all readings quickly, in rising-current order, and let the battery rest between attempts.
Logging r over a battery's life
A single measurement diagnoses today; a log of measurements diagnoses the future. Record r with its date, temperature and state of charge each time you test — monthly for a working vehicle, quarterly for standby plant — and plot it. Healthy batteries drift slowly; a step change after a deep discharge or a hot summer marks damage done, and an accelerating rise is the classic end-of-life signature, typically arriving months before the battery actually fails to start or hold a load. Fleet operators automate exactly this with conductance testers that estimate the same quantity; the two-load method in a notebook achieves the same foresight for one battery and the price of two resistors.
Common mistakes
- Using the open-circuit voltage as one of the points carelessly. V at I = 0 is a valid point (it is E itself), but pairing it with one loaded reading throws away the slope check; two genuinely loaded points verify each other.
- Choosing two nearly equal currents. Dividing by a tiny (I2 − I1) magnifies every meter error. If your readings differ by 0.05 A, expect an r you cannot trust.
- Swapping the pairs. r = (V1 − V2)/(I2 − I1) needs the higher voltage paired with the lower current. Crossed pairs produce a negative r — nature's way of saying the data were muddled.
- Measuring V and I at different moments. A battery under load polarises and drifts; record each voltage while its current is actually flowing, and take both readings close together.
- Expecting r to be a universal constant. It shifts with temperature, state of charge and age. Quote it with its conditions, and compare like with like when tracking a battery's decline.
FAQ
Why use two loads instead of one measurement?
A single V and I pair mixes up the EMF and the internal resistance — infinitely many (E, r) pairs fit one point. Two points fix the straight line V = E − Ir, giving a unique slope (−r) and intercept (E).
Why not just measure the short-circuit current?
Shorting a battery can draw a huge current, overheating or damaging it (and the meter). The two-load method gets the same answer safely with ordinary loads.
Does internal resistance stay constant?
Not exactly — it rises as a battery ages, discharges or gets cold, which is why an old battery can show a healthy open-circuit voltage yet fail under load. Two-load measurements taken close together give a good snapshot value.
What does a negative r result mean?
It means the data are inconsistent with a passive source — usually the pairs were swapped, the battery was charging during one reading, or it recovered (voltage rose) between readings. Re-measure with clearly separated loads.
Can this method measure a phone power bank or USB supply?
Yes — Example 6 does exactly that. Regulated supplies show a very small effective r (their electronics fight the sag) until current limiting engages, after which the "line" folds sharply; measure below the limit.
Why does the open-circuit voltage alone mislead?
Because it contains no information about r. Example 4's battery shows 8.94 V open-circuit yet collapses under load. Any tester that reads only unloaded voltage will pass batteries that are already useless.
How is r related to a battery's amp-hour capacity?
Loosely at best. Capacity measures total charge stored; r measures how willingly it is delivered. Ageing usually raises r and lowers capacity together, but a high-capacity cell can still have a high r when cold.
What load values should I use for the two measurements?
One light (about a tenth of the expected maximum current) and one heavy (half to full working current), both safe for the source and the load resistors' power ratings.
Does the connecting leads' resistance count?
Yes — leads and contacts sit in series and add to the measured r, especially at car-battery currents where 0.027 Ω is the prize. Measure the voltage directly at the battery terminals to exclude them.
Can a source have zero internal resistance?
Only the idealised source of textbook diagrams. Every physical source has some r, though a good laboratory supply's feedback can hold its effective r to milliohms across its rated range.