Inductance Solver Calculator – Find L from Reactance XL = 2πfL
Use this free Inductance Solver to work backwards from a measured inductive reactance to the inductance itself. If you know XL at a known frequency — from a datasheet, a simulation or a bench measurement — this finds L.
Most reactance calculations run forwards: take an inductance, apply a frequency, get XL. Real bench work often runs the other way. A coil arrives unlabelled, or a datasheet quotes a choke's impedance at a test frequency, or a simulation specifies the reactance a filter needs — and the question is what inductance stands behind the number. Because XL = 2πfL is a simple proportion, the reverse calculation is a single division, L = XL/(2πf). This solver performs it and reports the answer in henries and millihenries, the units in which real coils are specified and sold.
The catch — and it is the whole subtlety of the page — is that reactance is not a property of the coil alone. It is a property of the coil at a frequency, growing in direct proportion as frequency rises: the same winding that presents 100 Ω at 50 Hz presents 800 Ω at 400 Hz and 100,000 Ω at 50 kHz. An inductance, by contrast, is (to a good approximation) a fixed property of the winding's geometry and core. The solver's job is to strip the frequency back out of a reactance measurement and recover that fixed property — which is why the frequency is a compulsory input, not an optional refinement.
Working backwards like this is how inductors are characterised in practice. LCR meters apply a known test frequency, measure the reactance, and divide — exactly this formula — before printing "318 mH" on their displays. Filter designers run it in reverse too: the crossover or matching network demands a certain XL at a certain frequency, and the division converts that demand into a component value to wind or buy. Enter the reactance in ohms and the frequency in hertz, and the solver returns the coil behind the number.
Formula
XL = 2πfL, rearranged: L = XL / (2πf)
The quantity 2πf is the angular frequency ω, so the formula is often written L = XL / ω — reactance per unit angular frequency. The inverse design form is just as useful: to obtain a chosen reactance at a chosen frequency, this same division tells you the coil to build. And if instead you know L and want the frequency at which it shows a given reactance, f = XL / (2πL). Units are unforgiving here: XL in ohms and f in hertz give L in henries. Since practical coils live in millihenries and microhenries, expect small decimals — 0.31831 H is the same coil as 318.31 mH, and the solver prints both so the number can be matched against component markings directly.
| Symbol | Meaning | Units |
|---|---|---|
| L | inductance — the coil's fixed property | henries (H), mH, µH |
| XL | inductive reactance at the stated frequency | ohms (Ω) |
| f | frequency at which XL applies | hertz (Hz) |
| ω | angular frequency, ω = 2πf | radians per second (rad/s) |
| Rw | winding resistance — the coil's unwelcome series partner | ohms (Ω) |
Reactance is not resistance: what the division is really undoing
An inductor opposes alternating current not by consuming energy but by timing. The changing current builds a magnetic field; the field, fighting back through Faraday's law, generates a voltage that opposes the change. The result is a current that lags the applied voltage by a quarter-cycle and an opposition that scales with how fast the current tries to change — that is, with frequency, and with the inductance that measures how much field a given current builds. XL = 2πfL is the product of those two factors, and solving for L divides the frequency factor back out, leaving the geometry: turns, area, core permeability, all frozen into one number.
The lag has a measurement consequence the original FAQ hints at. A real coil is L in series with its winding resistance Rw, so its terminal impedance is Z = √(Rw² + XL²), and a naive V/I measurement returns Z, not XL. When Rw is small beside XL the distinction is pedantic — with Rw = 5 Ω and XL = 100 Ω, Z = 100.12 Ω and the error is an eighth of a percent. But measure a small coil at a low frequency — Rw = 5 Ω, XL = 8 Ω — and Z = 9.43 Ω overstates the reactance by 18%, and the inductance with it. The cure is to measure at a frequency where XL dwarfs Rw, or to subtract: XL = √(Z² − Rw²) with Rw taken from an ohmmeter.
Two more real-world effects bend the ideal proportion. At high frequencies the current crowds towards the wire's surface (skin effect), raising Rw and eventually making the simple model creak; and a ferromagnetic core's permeability — hence L itself — drifts with frequency, temperature and signal level, saturating outright if the current pushes the core too far. None of this invalidates the solver; it defines its jurisdiction. Within the audio and lower radio ranges, with sane signal levels, L = XL/(2πf) is exact for engineering purposes — which is why every LCR meter on every bench trusts it.
How to use
- Enter the inductive reactance XL in ohms.
- Enter the frequency at which that reactance applies, in hertz.
- Click "Calculate" for the inductance in henries and millihenries.
- Verify by running the result forwards: 2πfL should return your XL. If you measured the reactance as V/I on a real coil, first check that the winding resistance is small beside XL — if not, correct it with XL = √(Z² − Rw²).
Worked examples
Example 1 — a mains-frequency coil. A coil shows a reactance of 100 Ω on a 50 Hz supply.
L = 100 / (2π × 50) = 100 / 314.16 = 0.31831 H, which is 318.31 mH.
Check: at 50 Hz this coil's reactance is 2π × 50 × 0.31831 = 100 Ω, as measured.
Example 2 — a heavier reactance at 60 Hz. A ballast coil presents XL = 1000 Ω at 60 Hz. L = 1000 / (2π × 60) = 1000 / 376.99 = 2.65258 H (2652.58 mH). Large iron-cored chokes for lighting ballasts and power supplies live in this henry-scale territory — the low frequency demands a lot of inductance for a lot of reactance.
Example 3 — an RF choke. A choke in a transmitter output stage must present 500 Ω at 1 MHz. L = 500 / (2π × 106) = 79.58 µH. At radio frequencies the microhenry reigns: a few dozen turns on a small former, because the enormous 2πf does most of the work.
Example 4 — a loudspeaker crossover inductor. A first-order crossover at 1 kHz needs the series inductor to present XL = 25.13 Ω at the crossover frequency. L = 25.13 / (2π × 1000) = 4 mH. Check: 2π × 1000 × 0.004 = 25.13 Ω — the standard 4 mH crossover coil falls straight out of the division.
Example 5 — a motor winding. A small motor's winding measures XL = 37.7 Ω at 50 Hz. L = 37.7 / (2π × 50) = 0.12 H (120 mH). Motor designers quote winding inductance in exactly this range, and it is this L — with the winding resistance — that sets the motor's starting current and its power factor.
Example 6 — one coil, two frequencies. Take Example 1's 318.31 mH coil onto a 400 Hz aircraft supply: XL = 2π × 400 × 0.31831 = 800 Ω — exactly eight times the 50 Hz reactance, because 400/50 = 8 and the proportion is exact. This is the fastest sanity check in the topic: scale the frequency, scale the reactance, and if a measurement disagrees, the coil's core is drifting or saturating.
Inductance from reactance in real life
LCR meters and component testers. The £20 component tester on a hobby bench and the precision bridge in a standards lab run the same division: apply a known frequency, measure reactance, divide by 2πf. The test frequency (100 Hz, 1 kHz, 100 kHz) is printed in the manual because the answer's validity rides on it.
Identifying unmarked coils. Salvaged and unlabelled inductors are bench mysteries until measured. A signal generator, a resistor and this calculation turn a V/I measurement at any convenient frequency into a value in millihenries — the standard first step in reverse-engineering a power supply.
Crossover and filter design. Filter recipes are written in reactances at the corner frequency ("make XL equal to the load resistance at 1 kHz"). The solver is the translation layer between those recipes and the parts catalogue, as Example 4 shows.
Ballast and choke specification. Fluorescent and discharge-lighting ballasts are specified by the impedance they present at mains frequency. Working backwards gives the inductance the manufacturer wound — and the value a replacement must match, at 50 or 60 Hz as the case may be.
Motor and transformer diagnostics. A winding whose measured inductance has fallen from its nameplate value is a winding with shorted turns — the classic early warning of motor failure, detected by exactly this measurement long before the insulation fails outright.
Wireless-power and RFID coils. Coupled coils are tuned by measuring their reactance at the operating frequency (13.56 MHz for NFC) and trimming turns until L lands on the design value. The division is run dozens of times in a single prototyping session.
Quick reference: reactance of a 100 mH coil
| Frequency | XL = 2πfL | Regime |
|---|---|---|
| 50 Hz | 31.42 Ω | mains chokes |
| 60 Hz | 37.70 Ω | mains (Americas) |
| 100 Hz | 62.83 Ω | LCR-meter test tone |
| 400 Hz | 251.33 Ω | aircraft power |
| 1 kHz | 628.32 Ω | audio crossovers |
| 10 kHz | 6,283.19 Ω | ultrasonic drivers |
The straight-line law cuts both ways: if you need a target XL and the frequency rises by ten, the required inductance falls by ten. It is why mains equipment is full of iron and radio equipment is full of air — at 1 MHz, Example 3 needed only 79.58 µH to do what 2.65 H does at 60 Hz.
The alternative route: finding L through resonance
There is a second classical way to measure an unknown inductance, and it cross-checks this one. Connect the coil to a known capacitor, sweep the frequency, and find the resonance f0 where the current peaks; then L = 1/((2πf0)²C). Resonance methods are exquisitely sensitive — the peak is easy to locate precisely — and they measure L at a frequency you choose by choosing C. When the resonance answer and the reactance answer agree, the coil is well-behaved; when they drift apart with frequency, the core's permeability is wandering, and the honest specification is a curve of L against f rather than a single number.
The reactance route is also how an unknown coil is measured on a modest bench, and the procedure deserves stating because it inverts this calculator exactly. Feed the coil from a signal generator through a known series resistor, raise the frequency until the voltage across the resistor equals the voltage across the coil — at that point XL equals the known resistance, since the same current flows through both — and read the frequency. One division, L = XL/(2πf), returns the inductance with no LCR meter in sight. The method's accuracy rests on the coil's own winding resistance being small beside XL at the test frequency; where it is not, the measured voltages should be treated as phasors, or the frequency raised until the resistance is outvoted. Old hands used the identical trick with a headphone null and a bridge; the instruments changed, the division did not.
Common mistakes
- Quoting a reactance without its frequency. "This coil is 100 Ω" is meaningless — 100 Ω at 50 Hz is 318.31 mH; at 5 kHz it is 3.18 mH. The solver demands f as an input precisely because the pair (XL, f) is the measurement; either half alone is noise.
- Forgetting the 2π. L = XL/f instead of XL/(2πf) overstates the inductance 6.28 times. A 318 mH coil becomes a fictional 2 H — the most common arithmetic error in the topic.
- Treating a V/I measurement as pure reactance. The terminal ratio is Z = √(Rw² + XL²). With a resistive winding or a low test frequency, failing to subtract Rw inflates L — by 18% in the concept section's example.
- Unit slips between H, mH and µH. 0.31831 H, 318.31 mH and 318,310 µH are one coil. An answer checked against a component's marking in the wrong unit looks a thousand times wrong while being exactly right.
- Measuring a cored coil at the wrong signal level. Ferrite and iron permeability depend on flux level; a coil characterised at a whisper may show a different L at working current, and a saturating core shows less. Measure near the intended operating conditions.
FAQ
Why must I know the frequency?
Reactance is not a fixed property of the coil — it grows in direct proportion to frequency. The same 100 Ω could come from a big coil at low frequency or a small coil at high frequency, so XL alone cannot fix L.
How could I measure XL in practice?
Apply a known AC voltage at a known frequency, measure the RMS current, and divide: XL ≈ V/I (after allowing for the winding's resistance). LCR meters do this automatically at their test frequency.
Does the coil's resistance spoil the result?
Slightly. A real coil's impedance is √(R² + XL²), so if R is not small compared with XL, treating the whole impedance as reactance overestimates L a little.
What frequency should I use to measure an unknown coil?
One near its intended working frequency, high enough that XL comfortably exceeds the winding resistance (a factor of ten makes the Rw error about half a percent) but below the coil's self-resonant frequency, where its own stray capacitance joins in and the simple model fails.
Why does the same coil give different L on different LCR meters?
Because meters test at different frequencies and levels, and real inductance — especially with ferrite cores — genuinely varies with both. A discrepancy of a few percent is normal; a large one means the core is dispersive or saturating, and the datasheet's stated test conditions decide which reading to trust.
Can I find L from a DC measurement?
No. At DC (after the initial transient) an inductor is just its winding resistance — the reactance is zero at f = 0 and the formula divides by zero. Inductance only reveals itself to changing current; that is the entire content of XL = 2πfL.
How is inductance related to the number of turns?
For a given core and geometry, L grows with the square of the turns: double the turns, quadruple the inductance (and roughly double the winding resistance). This is why small changes in turns count are such a powerful trimming tool in coil production.
What is a henry, in plain terms?
One henry is the inductance that generates one volt of back-EMF when the current changes at one amp per second. It is a large unit — power chokes reach it, signal coils rarely do — which is why mH and µH dominate component catalogues.
Does the solver work for coupled coils and transformers?
For a single winding measured with the other open-circuited, yes — that is the standard way to obtain primary or secondary inductance. With the other winding shorted, the same measurement yields the much smaller leakage inductance, a different (and also useful) quantity; the frequency discipline is identical.
Why do datasheets quote impedance at 100 kHz for power inductors?
Because switch-mode converters operate there, and at 100 kHz the winding's behaviour — core loss, skin effect, self-capacitance — is part of the component's real performance. Quoting XL (or Z) at the application frequency is the manufacturer doing this page's measurement under honest conditions.