RL Time Constant Calculator – τ = L/R & Current Growth Percentage

Use this free RL Time Constant Calculator to find how quickly the current grows in a resistor–inductor circuit, using τ = L ÷ R, and to see what percentage of the final current is reached after any time t.

Connect a battery to a resistor and the current arrives instantly, as far as any ordinary measurement can tell. Connect it through an inductor and the current takes its time — rising quickly at first, then ever more reluctantly, approaching its final value along an exponential curve that mathematically never quite arrives. The single number governing that whole curve is the time constant, τ = L/R. It compresses the circuit's entire personality into one figure with units of seconds: after one τ the current has covered 63.2% of its journey; after 5τ it is within 1% of home and engineers declare it settled. Every inductor circuit — relay, motor winding, converter, electromagnet — has this number ticking inside it.

The ratio's direction is worth feeling in your hands. Inductance L is the coil's stubbornness, its refusal to let current change; resistance R is the circuit's ability to dissipate the inductor's stored energy and impose the final state. A big L with a small R gives a long, lazy τ — a superconducting magnet's current can take hours to establish and, once established, persists almost forever. A small L with a big R gives microseconds. Note the contrast with the capacitor's τ = RC, where resistance slows the process; here resistance hastens it, because a larger R both lowers the final current and bleeds the field's energy faster. Same exponential family, opposite instincts — a classic examination trap, and a real design lever.

RL Time Constant Calculator — formula and diagram

This calculator finds τ from L and R, and with the optional supply voltage and elapsed time it evaluates the growth curve itself: the final current V/R, and the percentage and actual current reached at any moment t. It is the natural companion to the inductor-voltage calculator — that page prices the instantaneous slope of the curve this page draws. Together they answer the two questions every inductive circuit asks: how big is the voltage while things change, and how long does the change take?

final I = V/R initial slope: reaches final in one τ — if it could keep it up I t

Formula

τ = L ÷ R  •  τ = time constant (s), L = inductance (H), R = total series resistance (Ω) — including the coil's own winding resistance, which beginners forget and designers cannot. While the current grows from zero: I(t) = (V ÷ R) × (1 − e−t/τ), where V/R is the final (steady) current. When the supply is removed and the current decays through the same resistance: I(t) = I₀ × e−t/τ. Milestones of the growth curve: 1τ → 63.2%, 2τ → 86.5%, 3τ → 95.0%, 4τ → 98.2%, 5τ → 99.3%. The energy stored once settled is U = ½ × L × I², all of which the resistor must absorb as heat during switch-off decay.

SymbolMeaningUnits
τtime constant — the curve's characteristic timeseconds (s); ms and µs in practice
Linductance of the coilhenries (H)
Rtotal resistance in the loop (source + wiring + winding)ohms (Ω)
Vsupply voltagevolts (V)
I(t)current at time t after switch-onamps (A)
eEuler's number ≈ 2.718 — the base of the exponential—

Why exponential? The shrinking difference

The curve's shape is forced by one fact: the inductor's current grows at a rate proportional to the voltage across the inductor, and that voltage is whatever the resistor leaves behind. At switch-on the current is zero, the resistor drops nothing, the full V sits across L, and the current ramps at its steepest, V/L amps per second — steep enough that, could it sustain the pace, it would reach the final current in exactly one time constant (the dashed tangent in the diagram). But every amp gained drops I × R across the resistor, stealing voltage from the inductor, so the growth slows in proportion to the distance remaining. "Rate proportional to what's left" is the signature of the exponential: the same mathematics as cooling coffee, discharging capacitors and decaying nuclei, which is why τ-thinking transfers across all of physics.

The decay tells the same story backwards with the signs flipped. Disconnect the supply (giving the current a path — through a freewheel diode or the same resistor) and the inductor becomes the source, spending its stored ½LI² to keep its own current alive. The current falls by the same 63.2%-per-τ rhythm: 36.8% remains after one τ, 0.67% after five. Deny the current a path — snap a switch open — and the inductor raises its voltage without limit in principle, striking an arc to make a path, which is the switch-off spike of the inductor-voltage page. Growth and decay are one curve read in two directions, and τ conducts both.

t = τ 36.8% remains switch-off decay: I = I₀ e^(−t/τ) I

How to use

  1. Enter the inductance L in henries (50 mH = 0.05 H).
  2. Enter the total resistance R in the loop — supply resistance, wiring, and crucially the coil's own winding resistance, which for small coils is most of it.
  3. Optionally enter the supply voltage V to get the final current V/R.
  4. Optionally enter a time t (in seconds) to get the percentage and value of current reached by then.
  5. Click "Calculate" for τ in seconds and milliseconds, the 5τ settling time, and your requested growth figures. Rule of thumb for sanity: at t = τ the answer must say 63.2% — if it doesn't, a unit has slipped.

Worked examples

Example 1 — the reference circuit. A coil of L = 0.2 H is connected through R = 10 Ω to a 20 V supply.
τ = L ÷ R = 0.2 ÷ 10 = 0.02 s = 20 ms.
Final current = V ÷ R = 20 ÷ 10 = 2 A.
At t = 0.02 s (exactly one τ): fraction = 1 − e−1 = 63.21%, so I = 2 × 0.6321 = 1.264 A.
The current is effectively settled after 5τ = 0.1 s. By then the field stores U = ½LI² = ½ × 0.2 × 2² = 0.4 J — the energy a switch-off must dispose of.

Example 2 — a relay coil's snap. A small relay coil has L = 0.05 H and total circuit resistance R = 50 Ω, driven from V = 5 V.
τ = 0.05 ÷ 50 = 0.001 s = 1 ms; final current = 5 ÷ 50 = 0.1 A.
At t = 0.002 s (2τ): fraction = 1 − e−2 = 86.47%, so I = 0.0865 A.
The relay pulls in once the current (and hence magnetic pull) is high enough — typically within 2–3 ms — which is why relay datasheets quote operate times in single-digit milliseconds.

Example 3 — a crane electromagnet's patience. A lifting magnet has L = 10 H and R = 5 Ω on a 100 V supply.
τ = 10 ÷ 5 = 2 s; final current = 20 A; settled after 5τ = 10 s.
At t = 2 s the current is 20 × 0.6321 = 12.64 A — the magnet is at roughly two-thirds strength and still climbing. Operators of big electromagnets and MRI magnet engineers alike plan around these seconds-long exponentials; nothing about a henry-scale coil is instant.

Example 4 — a fast electronic load. An inductor of L = 1 H in a test rig faces R = 100 Ω and V = 50 V.
τ = 1 ÷ 100 = 0.01 s = 10 ms; final current = 0.5 A.
At t = 0.03 s (3τ): fraction = 1 − e−3 = 95.02%, giving I = 0.5 × 0.9502 = 0.4751 A. Same inductance as a hefty choke, but the hundred-ohm resistor makes it twenty times faster than Example 1's circuit — R is the accelerator pedal of τ.

Example 5 — designing a time constant. A timing circuit needs τ = 1 ms and the available resistor is R = 20 Ω.
L = τ × R = 0.001 × 20 = 0.02 H = 20 mH.
Check with the calculator: L = 0.02, R = 20, V = 10 gives τ = 1 ms, final current 0.5 A, and at t = 1 ms the current is 0.5 × 0.6321 = 0.316 A. The rearrangement L = τR is how such parts are specified before a single coil is wound.

Example 6 — an audio crossover's speed. A woofer crossover inductor of L = 0.002 H (2 mH) works into the speaker's R = 8 Ω.
τ = 0.002 ÷ 8 = 0.00025 s = 0.25 ms; settled in 5τ = 1.25 ms.
Audio waveforms change on millisecond scales, so a quarter-millisecond time constant is exactly the right neighbourhood: fast enough to follow the music's broad shape, slow enough to resist the treble the crossover exists to divert.

RL time constants in real life

Relay and contactor timing. Example 2's millisecond exponentials set how fast relays pull in and drop out. Designers exploit τ deliberately — a larger R (or a series resistor with a shorting contact) speeds release when a contactor must open promptly, for instance in safety circuits.

Ignition and injector drivers. Fuel injectors and ignition coils are RL circuits whose current must reach a target within a crank-angle window. Engine controllers measure and adapt to τ as coils age and warm, because a millisecond late at 6,000 rpm is a misfire.

MRI and superconducting magnets. A superconducting magnet's R is nearly zero, so τ = L/R stretches to hours or days: ramping the current is a slow ceremony, and once at field the current persists with almost no decay — the flip side being that a quench must dump megajoules of ½LI² safely.

Switch-mode converters. A converter's inductor current ramps in controlled slices of the exponential — the switch turns off long before settling, so the current ripples in the curve's steep early region. τ relative to the switching period decides whether the ripple is a gentle slope or a wild swing.

Motor windings. A DC motor's armature is an RL circuit; its electrical τ (often a few milliseconds) limits how fast torque can respond, while the mechanical inertia adds a far slower time constant of its own. Drives are tuned around both.

Fault-current limitation. When a short circuit strikes a DC system, the current does not jump — it climbs this page's exponential, with τ set by the network's L and R. Protection engineers use the breathing room τ provides: breakers race the curve, and reactors are added to stretch τ deliberately.

growth after 1τ: 63.2% there growth after 2τ: 86.5% there — each τ closes 63.2% of what remains

Quick reference: the exponential's milestones

Elapsed timeGrowth: % of final currentDecay: % of initial current left
0.5τ39.35%60.65%
1τ63.21%36.79%
2τ86.47%13.53%
3τ95.02%4.98%
4τ98.17%1.83%
5τ99.33%0.67%

Memorise the first row of milestones and you can sketch any RL transient freehand: each time constant closes 63.2% of the remaining gap. It is also the fastest sanity check on this calculator's output — if the percentage at your t doesn't sit between the milestones bracketing t/τ, an input is in the wrong unit.

The current's half-life: another way to read the curve

Radioactivity taught physics to think in half-lives, and the RL decay has one too: the time for the current to fall to half is t½ = τ × ln 2 ≈ 0.693τ. For Example 1's circuit that is 0.693 × 20 ms = 13.86 ms per halving — after 27.7 ms a quarter remains, after 41.6 ms an eighth. Some engineers prefer half-life language because repeated halving is easy mental arithmetic; the two descriptions are the same exponential in different clothes, convertible by the single factor ln 2. Growth has the mirror notion — the time to cover half the remaining distance is the same 0.693τ — which is why the curve feels brisk at first and interminable near the end: the last few percent are many half-lives deep.

Common mistakes

  • Forgetting the winding resistance. R is the whole loop's resistance. A coil marked 0.2 H with 9 Ω of winding resistance in a circuit with a 1 Ω source has R = 10 Ω, not 1 Ω — a tenfold τ error from one omission.
  • Entering millihenries as henries. 2 mH is 0.002 H. The prefix errors are merciless: mH inflates τ by 1,000, µH by 1,000,000.
  • Expecting the current to finish at 1τ. One time constant is 63.2%, not 100%. Circuits quoted as "settled" need 5τ; precision analogue work may wait 7τ or more. Budgeting 1τ for full current under-designs everything downstream.
  • Importing the RC rule backwards. For capacitors, more R means slower (τ = RC). For inductors, more R means faster (τ = L/R). Mixing the two inverts the design: adding resistance to speed a relay's release works precisely because this is RL, not RC.
  • Breaking the decay path. The decay formula assumes the current has somewhere to flow. Open-circuiting an inductor does not give an infinite-τ decay — it gives an arc, a spike, and possibly a damaged switch. Always provide the path the mathematics assumes.

FAQ

Why doesn't the current jump straight to V/R?
As the current starts to grow, the inductor's changing magnetic field induces a back-EMF that opposes the growth. The current can only creep up exponentially — fast at first, then slower and slower as the back-EMF fades.

How is this different from an RC circuit?
The maths is the same shape, but the roles swap: an RC circuit has τ = RC and its voltage charges up exponentially, while here τ = L/R and the current grows. In both cases 5τ is the practical "fully settled" time.

What if I switch the circuit off?
The current decays with the same time constant: I(t) = I₀ e−t/τ. The inductor tries to keep the current flowing, which is why opening a switch on a large inductor can produce a spark — the stored energy has to go somewhere.

Why 63.2% — where does that number come from?
It is 1 − 1/e. At t = τ the exponent is −1, and e⁻¹ = 0.3679, so the current has covered 1 − 0.3679 = 0.6321 of its rise. The odd-looking figure is just Euler's number wearing overalls; the decay milestone is the mirror: 36.79% = 1/e remaining.

Can τ be measured with an oscilloscope?
Easily — it is one of the classic bench measurements. Apply a step voltage, display the current (or the resistor's voltage), and read the time to reach 63.2% of the final value. That time is τ, and L = τR follows. The initial slope gives an independent check: it equals V/L.

What if the resistance is truly zero?
Then τ is infinite and the current ramps linearly forever under a fixed voltage — V = L dI/dt with nothing to stop it. Superconducting magnets approach this limit, which is why their supplies control the ramp explicitly and their protection systems treat the stored energy with such respect.

Does τ change with the supply voltage?
No. τ = L/R contains no V. A bigger supply raises the final current and the initial slope in the same proportion, so the curve scales vertically but keeps its timing — the percentage milestones are identical at 5 V and 500 V.

Why do relays sometimes have a resistor or diode across the coil?
The diode gives the switch-off current a path, clamping the spike at the price of a slower decay (the decay τ becomes L divided by the coil's own small resistance — long). A resistor in series with the diode raises the decay loop's R, shortening τ and letting the relay release faster, at the price of a higher but controlled spike. It is τ-engineering in its purest form.

How does temperature affect τ?
Through R: copper winding resistance rises about 0.4% per °C, so a hot coil's τ shrinks slightly while its final current falls. Inductance is nearly temperature-independent for air cores; ferrite cores drift somewhat. Precision timing circuits allow for both.

Is the same τ hiding inside AC circuits?
Yes — an RL circuit's response to AC is governed by the ratio ωL/R, and ωτ = ωL/R compares the drive's speed with the circuit's own. At frequencies where ωτ ≫ 1 the inductance dominates and the current lags nearly 90°; where ωτ ≪ 1 the circuit behaves resistively. The time constant is the frequency story told in seconds.

Thomas Becker

Thomas Becker

Physics Writer · Electricity & Magnetism

Thomas Becker creates and reviews our magnetism and electrostatics calculators at CalcVIP. Every calculator is checked against hand-worked examples before it is published, so the formula, the diagram and the answer all agree.