Capacitive Reactance Calculator – XC = 1/(2πfC) & Current

Use this free Capacitive Reactance Calculator to find XC = 1 ÷ (2πfC) — the opposition a capacitor offers to alternating current. Add the supply voltage and the calculator also finds the current that flows.

A capacitor in an AC circuit is a gatekeeper with a stopwatch. It passes alternating current — not by letting charge through, for no charge ever crosses its gap — but by charging and discharging in rhythm with the supply, and the opposition it offers to that rhythm is the capacitive reactance XC = 1 ÷ (2πfC). This calculator finds XC from frequency and capacitance (with unit selectors down to picofarads), and, if you add the supply voltage, the current that flows: I = V ÷ XC.

Everything distinctive about XC flows from the 1 ÷ f shape of the formula. Raise the frequency and the reactance falls — the capacitor has less time to charge each half-cycle, so it never builds the voltage that would choke the current. Lower the frequency and reactance climbs, reaching infinity at DC: a charged capacitor on a steady supply is an open door slammed shut. Between those extremes lies every coupling capacitor, crossover network, capacitive dropper and touch sensor in electronics, all positioned somewhere on this one hyperbola.

Capacitive Reactance Calculator — formula and diagram

Reactance deserves respect as a different species from resistance, though both are measured in ohms. A resistor converts electrical energy to heat, permanently. An ideal capacitor borrows energy into its electric field for a quarter-cycle and returns every joule in the next — its current and voltage sit 90° out of phase, so the average power is zero. Real capacitors warm slightly (their small ESR sees to that), but the reactance itself is a lossless gatekeeper: it limits current by timing, not by friction.

C AC ~ I XC = 1/(2πfC)

Formula

Capacitive reactance XC = 1 ÷ (2πfC)  •  current I = V ÷ XC = 2πfCV  •  XC in ohms (Ω), f in hertz (Hz), C in farads (F), V in volts, I in amps

The rearrangements map the design space. To hit a target reactance at a known frequency, C = 1 ÷ (2πf XC); to find where a given capacitor reaches a given reactance, f = 1 ÷ (2πC XC). The current form I = 2πfCV is worth its own line: it says the current through a capacitor is proportional to frequency, capacitance and voltage alike — double any one and the current doubles. Two scaling laws follow and should become reflexes: XC is inversely proportional to f (ten times the frequency, one tenth the reactance) and inversely proportional to C (a capacitor ten times bigger passes ten times the current at the same voltage). Capacitance units are the practical trap: the formula wants farads, so µF must be multiplied by 10−6 and pF by 10−12 — this calculator's unit selector exists precisely to make that conversion unmissable.

SymbolMeaningUnits
XCcapacitive reactance — opposition to ACohms (Ω)
ffrequency of the alternating supplyhertz (Hz)
Ccapacitancefarads (F); 1 µF = 10−6 F
Vsupply voltage (RMS, for AC work)volts (V)
Icurrent through the capacitor (RMS)amps (A)

Why the current leads: the 90° story

Connect a capacitor to a sine-wave supply and watch the phase. Current flows hardest not when the voltage is greatest but when it is changing fastest — at the zero crossings — because current is the rate of charging, and charging is fastest when the target is moving fastest. When the voltage peaks, it momentarily stops changing, the capacitor is full to that voltage, and the current falls to zero. The result: the current wave runs exactly a quarter-cycle — 90° — ahead of the voltage wave, summarised in the mnemonic "ICE": in a capacitor (C), the current (I) comes before the EMF (E). No energy is lost in this dance; the field absorbs power for a quarter-cycle and returns it in the next, so the average over a cycle is zero even while ammeters register a healthy current.

This phase behaviour is not decoration. It is why capacitors correct power factor in factories (their leading current cancels motors' lagging current), why a series capacitor can drop voltage without the heat a resistor would make (the capacitive dropper of Example 5), and why XC must be combined with resistance by Pythagoras, not addition, when both are present: impedance Z = √(R² + XC²). Treat reactance as resistance with a phase attached, and every formula on this page slots into the wider AC theory without contradiction.

current I — peaks first voltage V — peaks a quarter-cycle later I leads V by 90° in a capacitor ("ICE")

How to use

  1. Enter the AC frequency f in hertz — 50 or 60 for mains work, the signal frequency for audio and radio work.
  2. Enter the capacitance and choose its unit (µF is pre-selected; nF and pF are there for RF parts).
  3. Optionally enter the supply voltage to have the current calculated as well.
  4. Click "Calculate" to get XC in ohms, and the current if a voltage was supplied.
  5. Sanity-check with the scaling law: doubling the frequency should halve XC. If it does not, a unit — usually the capacitance prefix — has slipped.

Worked examples

Example 1 — a capacitor on the mains. A 10 µF capacitor is connected to a 50 Hz supply.
XC = 1 ÷ (2π × 50 × 10 × 10−6) = 318.31 Ω.
On a 230 V supply the current is I = 230 ÷ 318.31 = 0.72 A — nearly three-quarters of an amp flowing through a component no charge ever crosses, dissipating (ideally) no power at all. The reactive power involved is 230 × 0.72 ≈ 166 VAR, borrowed and returned twice per cycle.

Example 2 — the same capacitor in America. At 60 Hz, XC = 1 ÷ (2π × 60 × 10 × 10−6) = 265.26 Ω, and from a 120 V supply the current is 120 ÷ 265.26 = 0.45 A. The 20% frequency rise cut the reactance by a sixth — the inverse law at work, and one reason equipment designed for 50 Hz runs slightly differently on 60 Hz.

Example 3 — a tweeter crossover. A simple first-order crossover feeds a tweeter through 4.7 µF. At 5 kHz, XC = 1 ÷ (2π × 5000 × 4.7 × 10−6) = 6.77 Ω — comparable to the tweeter's own 8 Ω, so plenty of signal passes. Down at 500 Hz the same capacitor presents 67.7 Ω and the bass is throttled tenfold: the rising reactance with falling frequency is the filter.

Example 4 — radio frequencies. A 100 pF capacitor at 100 MHz: XC = 1 ÷ (2π × 108 × 100 × 10−12) = 15.92 Ω. At radio frequencies even picofarads are low roads for current — which is why RF circuits treat every stray capacitance as a component, and why a few pF of coupling is a deliberate design value, not a leak.

Example 5 — the capacitive dropper. Cheap LED lamps and standby supplies drop mains voltage with a series capacitor instead of a hot resistor. A 1 µF capacitor at 50 Hz has XC = 3183.10 Ω, passing 230 ÷ 3183.10 = 0.072 A ≈ 72 mA — enough for a string of LEDs — while dissipating essentially no heat itself. The current is real; the waste is not. (The circuit is not isolated from the mains, which is why such supplies live in sealed lamps, never in anything a user can touch.)

Example 6 — watching the hyperbola. The 10 µF capacitor of Example 1 at 100 Hz: XC = 159.15 Ω, exactly half its 50 Hz value. At 400 Hz: 39.79 Ω, an eighth. Every doubling of frequency halves the reactance — after three doublings the capacitor that opposed the mains like a 318 Ω resistor passes current like a 40 Ω one.

Capacitive reactance in real life

Coupling and DC blocking. Between amplifier stages, a capacitor passes the AC signal while blocking the DC bias of the previous stage — XC chosen small at signal frequencies, infinite at DC. Every audio input you have ever used trusts this calculation to keep the music and drop the offset.

Loudspeaker crossovers. Example 3 is the world's simplest crossover: series capacitors feed tweeters, series inductors feed woofers, and the frequency where XC equals the driver's impedance sets the handover. Multi-way speakers are reactance budgets negotiated in decibels.

Capacitive droppers. Example 5's trick powers countless sealed, low-power devices from the mains without a transformer. The capacitor drops voltage by reactance — no heat, no bulk — at the price of no isolation, a bargain accepted only where the whole circuit is safely enclosed.

Power factor correction. Motors draw lagging current; banks of capacitors draw leading current; connected in parallel they cancel each other's reactive sloshing, leaving the supply to carry only the useful part. Utilities bill factories for poor power factor, so this page's formula, at cabinet scale, is a financial instrument.

Touch sensing. A fingertip changes a sensor's capacitance by a picofarad or so; the controller detects it by watching the current at a fixed frequency, I = 2πfCV. Higher drive frequencies make tinier capacitances measurable — the same reason Example 4's 100 pF is a wide-open road at 100 MHz.

Filtering and bypassing. To power-supply rails, a bypass capacitor is a frequency-dependent short circuit: at the ripple frequency its XC must be far below the load impedance, so the ripple takes the capacitor's path instead of the circuit's. Choosing the value is this formula aimed at a target reactance.

50 Hz → 318 Ω 100 Hz → 159 Ω 200 Hz → 80 Ω XC (ohms) f (hertz), C = 10 µF the hyperbola: reactance falls as 1/f

When XC meets XL: resonance

Put a capacitor and an inductor in series and their reactances fight: XL rises with frequency, XC falls, and at one frequency they are exactly equal and cancel — resonance. There the pair presents only its resistance, current peaks, and the voltages across L and C can each dwarf the supply. The condition XL = XC gives the resonant frequency f = 1 ÷ (2π√(LC)). Take the two reference components from this batch: L = 0.5 H and C = 10 µF resonate at 1 ÷ (2π√(0.5 × 10 × 10−6)) = 1 ÷ (2π × 2.236 × 10−3) ≈ 71 Hz, where each reactance is about 224 Ω and the series pair shows none of it. Radio tuners, metal detectors, induction heaters and wireless chargers all live on this cancellation point — two pages of this batch shaking hands.

XC with resistance: one worked impedance

Reactance rarely appears alone. Put a 100 Ω resistor in series with Example 1's capacitor (XC = 318.31 Ω at 50 Hz) and the opposition is the Pythagorean sum Z = √(100² + 318.31²) = √111,321 ≈ 333.6 Ω — noticeably less than the naive 418 Ω arithmetic sum. The current from 230 V is 230 ÷ 333.6 = 0.69 A, and it leads the supply voltage by arctan(318.31 ÷ 100) ≈ 72.6° rather than the pure capacitor's 90°, because the resistive part of the circuit pulls the phase toward zero. This is the calculation behind series RC droppers, snubbers and the input networks of countless power supplies — and the reason this page's XC is an ingredient, not the whole meal.

Quick reference: XC of a 10 µF capacitor

FrequencyXCCurrent from 230 V
50 Hz318.31 Ω0.72 A
60 Hz265.26 Ω0.87 A
100 Hz159.15 Ω1.45 A
400 Hz39.79 Ω5.78 A
1000 Hz15.92 Ω14.45 A

Read the current column as a warning label: the same capacitor that politely draws 0.72 A from the mains at 50 Hz would demand over 14 A at 1 kHz. Reactance is a frequency-dependent truce, renegotiated at every hertz.

Common mistakes

  • Entering µF as farads. Typing "10" for a 10 µF capacitor without the unit conversion shrinks XC by a factor of a million. The calculator's unit selector is the guardrail — use it, and in hand calculations write the 10−6 explicitly before touching 2π.
  • Treating XC as heat-dissipating resistance. A 318 Ω resistor on 230 V dissipates 166 W and glows; a 318 Ω reactance on 230 V passes the same 0.72 A and dissipates (ideally) nothing, because its current and voltage are 90° apart. Confusing the two leads to cooked components or, in dropper circuits, pleasant surprises — know which you have.
  • Adding XC and R arithmetically. In a series RC circuit the impedance is Z = √(R² + XC²), not R + XC, because the two voltages are 90° out of phase. The arithmetic sum overstates the opposition and understates the current.
  • Forgetting the voltage rating under resonance. In a series LC near resonance, the capacitor's own voltage can exceed the supply many times over (both reactances carry the full circulating current). Rate the capacitor for its own V = I × XC, not for the supply voltage.
  • Using a polarised electrolytic on raw AC. The formula does not care about polarity, but electrolytics do: reverse voltage destroys them. AC reactance duty needs film, ceramic or purpose-built non-polarised parts — or two electrolytics back to back, per the series page.

FAQ

Why does reactance fall as frequency rises?
At higher frequencies the capacitor charges and discharges more often, so charge flows more easily — the capacitor offers less opposition. At very high frequencies XC is nearly zero, while for DC (f = 0) it is infinite: a capacitor blocks steady DC.

Is reactance the same as resistance?
Both are measured in ohms and both limit current, but a reactance stores and returns energy instead of turning it into heat. An ideal capacitor wastes no power — the current and voltage are 90° out of phase.

How is XC different from XL?
They behave oppositely: XL = 2πfL grows with frequency, while XC = 1 ÷ (2πfC) shrinks. At one special frequency (resonance) they are equal and cancel out.

Does any charge actually pass through the capacitor?
No — the dielectric blocks it completely. What flows is charge onto one plate and off the other, in equal amounts, so the external circuit sees a current while the gap sees none. At the atomic level the "current" inside the dielectric is a shifting of bound charges, Maxwell's displacement current.

Why is there no reactance at DC after charging?
Because DC is the f = 0 limit: XC = 1 ÷ 0 = infinity. During the initial moment of connection current does flow — the charging transient of the RC page — but once the capacitor reaches the supply voltage, the flow stops entirely. A capacitor is a door that closes as it fills.

What is reactive power, in plain terms?
The rate at which energy sloshes between source and field without being consumed, measured in VAR. Example 1 sloshes about 166 VAR while consuming nothing. It matters because wires and transformers must be sized for the total current, sloshing included — power factor correction exists to shrink the slosh.

How do I choose a coupling capacitor?
Make its XC at the lowest signal frequency small compared with the load it feeds — a tenth is a common rule. For a 10 kΩ input and 20 Hz bass: C = 1 ÷ (2π × 20 × 1000) ≈ 8 µF, so a standard 10 µF part serves. The formula, run backwards from a target reactance, is the whole selection method.

Does XC depend on the voltage?
For ideal capacitors, no — reactance is set by f and C alone. Real parts drift a little: some ceramics lose capacitance under DC bias, and electrolytics vary with temperature and age, so precision AC work uses film or C0G ceramic parts whose C stays where the label put it.

Why do capacitors pass high frequencies better?
Because charging takes time and high frequencies allow less of it per half-cycle. The capacitor never accumulates enough charge to build a choking voltage before the supply reverses and starts emptying it again. Frequency is time pressure, and reactance is what pressure looks like in ohms.

What happens if XC is used at the wrong mains frequency?
Equipment with a capacitive dropper designed for 60 Hz runs about a sixth dimmer on 50 Hz, because XC is higher at the lower frequency and passes less current — Example 2's pair shows it: 265.26 Ω at 60 Hz against 318.31 Ω at 50 Hz. Transformers show the opposite sensitivity: a unit designed for 60 Hz may saturate on 50 Hz, where each longer cycle drives its core flux further. Frequency is effectively a component value in every reactive design, which is why nameplates state it.

Michael Chen

Michael Chen

Electronics Specialist

Michael Chen creates and reviews our electronics and circuits calculators at CalcVIP. Every calculator is checked against hand-worked examples before it is published, so the formula, the diagram and the answer all agree.