Mutual Inductance Calculator – M = k√(L₁L₂) & Induced EMF

Use this free Mutual Inductance Calculator to find how strongly two coils are linked, M = k × √(L₁L₂), and the EMF that a changing current in one coil induces in the other — the heart of every transformer and wireless charger.

Two coils near each other are never truly separate. Part of the flux made by the first coil threads the second, so a changing current in one induces a voltage in the other. The strength of that conversation is the mutual inductance M, measured in henries like self-inductance, and this calculator finds it from the two coils' own inductances and the coupling coefficient k — the fraction of the first coil's flux that actually reaches the second.

The formula M = k√(L1L2) has a hard ceiling built into it, and the ceiling is a theorem, not an engineering limitation: M can never exceed √(L1L2), the geometric mean of the two self-inductances, because no coil can link more flux than exists. k = 1 is the perfect-coupling limit approached by coils wound on a shared closed iron core; k ≈ 0.01–0.05 is the loose embrace of a phone resting on a charging pad; and k near zero is two coils minding their own business. Everything between is design.

Mutual Inductance Calculator — formula and diagram

The induced voltage is where M earns its keep: ε2 = −M × (ΔI1/Δt). The faster the primary current changes, the bigger the secondary voltage, in exact proportion — which is why transformers demand AC and why a wireless charger's electronics switch tens of thousands of times per second. This calculator also evaluates that induced voltage from M and the rate of change of current, so a coupling estimate becomes a voltage prediction in one visit.

coil 1: L₁, I₁ changes coil 2: L₂, ε₂ appears shared flux (the k fraction) dashed loop: leakage flux — links coil 1 only, never reaches coil 2

Formula

M = k × √(L1 × L2)  •  M and the L values in henries (H). The coupling coefficient k runs from 0 (no shared flux) to 1 (perfect coupling, approached by coils on a closed iron core). The induced voltage in coil 2 is ε2 = −M × ΔI1 ÷ Δt.

M has a second, equally valid definition worth holding alongside the first: it is the flux linkage produced in coil 2 per amp in coil 1, M = N2Φ21/I1 — and, remarkably, the same number describes the linkage in coil 1 per amp in coil 2. That reciprocity is why a single M suffices for both directions. A useful rearrangement finds the coupling from measurements: k = M ÷ √(L1L2) — measure the two self-inductances and the mutual, and k falls out. For two solenoids sharing an axis and core, M can also be built from geometry: M = μ0 × N1N2A ÷ l, the self-inductance formula with one N from each coil — note the turns now multiply (N1N2) rather than square.

SymbolMeaningUnits
Mmutual inductance between the two coilshenries (H)
kcoupling coefficient — fraction of flux shared— (0 to 1)
L1, L2self-inductances of the two coilshenries (H)
ε2voltage induced in coil 2volts (V)
ΔI1 ÷ Δtrate of change of coil 1's currentamps per second (A/s)

Leakage, reciprocity, and the meaning of k

Real flux divides into two portions: the mutual flux that links both coils and does the useful work, and the leakage flux that links only its own coil and is, from the transfer's point of view, wasted. k is essentially the mutual share. In a power transformer the leakage is engineered down to a percent or two with interleaved windings on a closed core; the small leakage that remains is not pure loss — it limits short-circuit currents and shapes the transformer's regulation. In an induction hob or a wireless charger, leakage is the design condition: the "secondary" (the pan, the phone) sits in air, most of the primary's flux misses it, and the electronics compensate with resonant capacitors and high frequency rather than iron.

Reciprocity deserves a pause, because it is not obvious and it is exact: the flux linkage in coil 2 per amp in coil 1 equals the linkage in coil 1 per amp in coil 2, always, whatever the coils' shapes. Drive the big coil and measure the small one, or drive the small and measure the big — M is the same. This symmetry (a consequence of energy conservation) is what allows a transformer to be analysed from either side, and what makes M a property of the pair, not of a direction.

k = 0.8: M = 32 mH same coils, air gap: k ≈ 0.3 coupling k →    (M = k × 40 mH for L₁ = 20 mH, L₂ = 80 mH) M

How to use

  1. Enter the two coils' self-inductances in millihenries — measure them with an LCR meter, or compute them with the solenoid inductance formula.
  2. Enter the coupling coefficient k: near 0.95–0.99 for coils sharing a closed iron core, 0.3–0.7 for coaxial air coils, 0.01–0.05 across a charging pad's gap.
  3. Click "Calculate" to get M, then optionally enter a current change and a time to see the induced voltage in the second coil.
  4. Sanity-check the result: M must come out at or below √(L1L2). If it does not, a units slip (µH entered as mH) is the usual cause.

Worked examples

Example 1 — coupled coils on a shared core. Two coils have L1 = 0.02 H and L2 = 0.08 H, coupled with k = 0.8.
M = k × √(L1L2) = 0.8 × √(0.02 × 0.08) = 0.8 × √0.0016 = 0.8 × 0.04 = 0.032 H = 32 mH.
Now let the current in coil 1 change by 3 A in 0.05 s (a rate of 60 A/s). The voltage induced in coil 2 is ε2 = M × ΔI ÷ Δt = 0.032 × 60 = 1.92 V — modest here because the change is slow; the same coils switched in microseconds would produce kilovolts.

Example 2 — perfect coupling. The same coils at the ideal limit k = 1: M = √(0.0016) = 0.04 H = 40 mH — the ceiling for this pair, and the same 60 A/s change would induce 0.04 × 60 = 2.4 V. Perfect coupling buys only 25% more than k = 0.8: coupling improvements have diminishing returns near the top.

Example 3 — a wireless-charging pair. Two small coils of L1 = L2 = 10 µH coupled across an air gap at k = 0.3: M = 0.3 × √(10 × 10) µH = 3 µH. Driven at 2 A changing in 10 µs (200,000 A/s, typical of a charger's switching), ε2 = 3 × 10⁻⁶ × 200,000 = 0.6 V per turn-equivalent — the raw induced voltage that resonant tuning then magnifies into useful charging power.

Example 4 — a power transformer's tight pair. Coils of L1 = 2 H and L2 = 0.5 H on a closed core at k = 0.98: M = 0.98 × √(2 × 0.5) = 0.98 × 1 = 0.98 H. A primary current change of 0.5 A in 0.01 s (50 A/s) induces ε2 = 0.98 × 50 = 49 V — mains-transformer territory, from a coupling figure only 2% short of perfect.

Example 5 — loose coupling, honest numbers. Coils of 1 mH and 4 mH separated so that k = 0.05: M = 0.05 × √(1 × 4) mH = 0.05 × 2 = 0.1 mH = 100 µH. A 1 A change in 1 ms (1,000 A/s) induces 10⁻⁴ × 1,000 = 0.1 V. Loose coupling is not useless — RFID tags and implant chargers live here — but the voltages are small and the electronics must be clever.

Example 6 — finding k from measurements. A pair measures L1 = 0.03 H, L2 = 0.027 H and M = 0.015 H. Then k = M ÷ √(L1L2) = 0.015 ÷ √(0.00081) = 0.015 ÷ 0.02846 = 0.527 — a moderately coupled air-core pair. This inversion is how coupling is actually measured on the bench: three inductance readings and one division.

Mutual inductance in real life

Transformers. The defining application: two windings, one core, k ≈ 0.98. M (with the turns ratio it implies) sets the voltage transformation, and the whole of AC power distribution rests on it.

Wireless charging. Phone and EV chargers are air-core pairs with k of a few percent to a few tenths; resonant capacitors on both sides cancel the leakage reactance, letting useful power cross a gap with no contacts to wear or corrode.

Induction hobs. The coil under the glass and the pan's base form a very loose transformer whose secondary is a short circuit — the induced currents heat the pan directly, which is why the hob itself stays cool.

RFID and NFC. A tag with no battery is powered by mutual inductance: the reader's alternating field induces a voltage in the tag's coil, the tag answers by modulating how much it loads the coupling — communication and power over one M.

Ignition and pulse coils. Where a fast current collapse in a low-voltage primary must become a kilovolt spike in the secondary, M and a huge dI/dt do the work — Example 1's arithmetic with the time shrunk a thousandfold.

Metal detectors and proximity sensors. A sense coil watches the mutual inductance to a driven coil; nearby metal perturbs the shared flux, changing M measurably — the same physics as the charger, used as an instrument instead.

charger coil phone coil air gap: k is small, so the electronics switch fast and resonate

Distance: why coupling falls off a cliff

For two coaxial loops separated by a distance large compared with their size, the field of one loop at the other falls as 1/d³ — it is a dipole field — and the shared flux, and hence M and k, fall with it. Double the gap and the coupling drops roughly eightfold. This cubic cliff explains the lived experience of inductive charging: a phone charges briskly in its sweet spot and barely at all a centimetre off it, and why EV charging pads are engineered to park the car's coil within a tight window. It also explains the design countermeasures — larger coils (whose "large compared with size" regime starts farther away), ferrite sheets that gather and guide flux, and alignment magnets that pull the pair into the sweet spot. Coupling is geometry, and geometry is unforgiving.

Measuring M, and what strong coupling does to resonance

The series trick in the FAQ deserves its numbers. Take the wireless pair of Example 3 (L1 = L2 = 10 µH, M = 3 µH) and connect the coils in series: aiding, the total is L1 + L2 + 2M = 26 µH; opposing, L1 + L2 − 2M = 14 µH. Two readings on an ordinary LCR meter, a difference of 12 µH, and M = 12 ÷ 4 = 3 µH — no bridge, no fluxmeter. Strong coupling has a second signature that surprises newcomers: put capacitors across both coils to resonate them at the same frequency, and as k rises the single resonance splits into two, an odd and an even coupled mode, whose separation grows with k. Wireless-power engineers live inside this effect — the split is why a tightly coupled charger detunes when the phone sits dead-centre, and why their control loops track frequency rather than assuming it. Mutual inductance, measured three ways here, is one of those quantities that repays being understood rather than merely computed.

The dot convention: M has a sign in practice

On circuit diagrams, coupled coils carry dots at one end of each winding, and the dots encode the sign that the magnitude-only formula omits. Currents entering both dotted terminals produce fluxes that aid each other; the induced voltage at a dotted terminal is positive when the current at the other dotted terminal is increasing. Wire one winding backwards and every secondary voltage flips phase — harmless in a power transformer, fatal in a feedback oscillator or a bridge circuit. The dots are simply the draftsman's way of recording how the coils were actually wound, which is the physical fact that decides the sign of M in ε = ±M dI/dt.

Quick reference: M versus k for the Example 1 pair (√(L₁L₂) = 40 mH)

Coupling kMutual inductance MTypical situation
0.104 mHcoils separated in air
0.3012 mHclose coaxial air coils
0.5020 mHcoils sharing a ferrite rod
0.8032 mHgood core, some leakage
0.9538 mHclosed iron core
1.0040 mHthe theoretical ceiling

Note the shape of progress: going from sloppy air coupling (k = 0.3) to a good core (k = 0.95) triples M — worthwhile, but nothing like the hundredfold gains available from raising the switching speed in the voltage formula.

Common mistakes

  • Letting M exceed √(L₁L₂). It cannot — that product's root is a hard ceiling set by energy conservation. A result above it means k > 1 was entered, or the units of the two L values disagree.
  • Mixing units between the two coils. L₁ in henries and L₂ in millihenries silently scales M by √1000 ≈ 31.6. Convert both to the same unit before the square root.
  • Expecting a DC current to induce a steady voltage. Only change induces. A steady primary current gives a steady flux and ε₂ = 0 — the reason transformers are AC devices.
  • Assuming k survives a change of position. k is a property of the pair in that geometry. Slide one coil sideways or tilt it and k can halve — recalculate (or re-measure) after any mechanical change.
  • Confusing M with the turns ratio. In an ideal transformer the voltage ratio equals the turns ratio, but M itself depends on both inductances and k; two pairs with the same turns ratio can have very different M.

FAQ

What decides the value of k?
Geometry and the core. Coils wound on the same closed iron core share almost all their flux (k ≈ 0.95–0.99). Coils side by side in air may share only a few percent, and k falls quickly with distance — the central challenge of wireless charging.

Does it matter which coil's current changes?
No — mutual inductance is symmetric: M is the same whether coil 1 drives coil 2 or the other way round. That is why the same M appears in ε₁ = M ΔI₂/Δt.

Why is there no induced EMF from a steady current?
Induction responds to change: ε₂ = M ΔI₁/Δt is zero when ΔI₁ = 0, however large the steady current is. This is why transformers need AC (or switched DC) to work.

Can k ever exceed 1?
No. k is the fraction of flux shared, so 1 is perfect sharing. M = k√(L₁L₂) can therefore never exceed √(L₁L₂) — a useful check on measurements.

How is M measured in practice?
Connect the coils in series twice — aiding, then opposing. The total inductance is L₁ + L₂ ± 2M, so M is a quarter of the difference between the two readings: a classic bridge-free measurement.

Why is wireless charging inefficient compared with a wired transformer?
Mostly the low k: with a few percent coupling, much of the primary's field links nothing and the transfer relies on resonance to recycle the energy. Modern pads still reach 70–80% efficiency — clever electronics compensating for loose geometry.

What does the minus sign in ε₂ = −M dI₁/dt mean?
Lenz's law: the induced voltage acts to oppose the change that made it. If coil 1's current rises, coil 2's induced voltage is oriented to drive a current whose flux fights the rise.

How does M depend on the number of turns?
For two solenoids on a shared axis, M = μ₀N₁N₂A/l — proportional to the product of the turns counts. Double either winding and M doubles; double both and it quadruples.

Does the core material change M?
Strongly. A shared core raises both self-inductances and, by guiding flux between the coils, raises k toward 1 — M gains twice over, which is why cored pairs outcouple air pairs by orders of magnitude.

Can mutual inductance be unwanted?
Often — it is the mechanism of crosstalk between adjacent cables and PCB traces, and of hum coupled from mains wiring into audio lines. The cures are distance (the 1/d³ fall), twisted pairs, and shielding.

Thomas Becker

Thomas Becker

Physics Writer · Electricity & Magnetism

Thomas Becker creates and reviews our magnetism and electrostatics calculators at CalcVIP. Every calculator is checked against hand-worked examples before it is published, so the formula, the diagram and the answer all agree.