RC Time Constant Calculator – τ = RC & % Charged

Use this free RC Time Constant Calculator to find τ = RC for a resistor–capacitor circuit, and to see how far a charging capacitor has got after any time t. After one time constant a charging capacitor reaches about 63% of its final charge — after 5τ it is effectively full.

The time constant τ = RC is the clock inside every resistor–capacitor circuit. It answers the question pure capacitance cannot: not how much charge a capacitor will eventually hold, but how fast it gets there. Charging through a resistor, a capacitor does not fill linearly — it rushes at first, then creeps, covering 63.2% of the remaining distance in each successive time constant, never quite arriving. τ is the single number that captures that curve: double R or double C and everything happens at half speed.

This calculator finds τ from any R and C (with unit selectors for Ω, kΩ, MΩ and F, mF, µF, so no powers-of-ten gymnastics), reports the practical "fully charged" time of 5τ, and — if you give it a moment t — tells you exactly what percentage of full charge the capacitor has reached by then, using % charged = (1 − e−t/τ) × 100. Timing circuits, debounce networks, soft-start ramps, camera flashes and the deliberate delays inside a thousand products are all specified in this language.

RC Time Constant Calculator — formula and diagram

The curve's shape is the same one nature uses for cooling coffee, decaying radioactivity and fading reverberation: exponential approach. Once you can read τ, you can read them all — and the deepest fact on this page is that the percentage milestones depend only on t ÷ τ, never on R, C or voltage separately. A nanosecond circuit and a minute-long timer trace the identical curve; only the clock speed differs.

R C charge rises: 63% at t = τ

Formula

Time constant τ = R × C  •  charging: % charged = (1 − e−t/τ) × 100  •  discharging: % remaining = e−t/τ × 100  •  τ in seconds when R is in ohms and C in farads

The units hide a gift: ohms × farads is seconds, exactly, with no conversion constant — a 1 Ω resistor and a 1 F capacitor make a 1 s time constant. Practical pairs scale neatly: kΩ × µF gives milliseconds (10³ × 10−6 = 10−3), and MΩ × µF gives seconds. The formulas rearrange for design: to hit a target τ with a chosen capacitor, R = τ ÷ C; with a chosen resistor, C = τ ÷ R. The underlying curve is V(t) = Vsupply × (1 − e−t/τ) for charging from empty, and V(t) = V0 × e−t/τ for discharging — the same exponential wearing its two hats. One more relation earns its place in filter design: an RC low-pass filter's cut-off frequency is fc = 1 ÷ (2πτ), so τ = 0.1 s corresponds to a cut-off near 1.6 Hz — timing and filtering are the same circuit read in two dialects.

SymbolMeaningUnits
τ (tau)time constant — the circuit's characteristic timeseconds (s)
Rresistance the capacitor charges/discharges throughohms (Ω)
Ccapacitancefarads (F)
telapsed time since charging/discharging beganseconds (s)
eEuler's number, 2.718… — the base of the exponentialpure number

Why charging slows down: the self-braking curve

A charging capacitor brakes itself. At the first instant it is empty, the full supply voltage stands across the resistor, the current is at its maximum (V ÷ R), and charge pours in. But every coulomb that arrives raises the capacitor's own voltage, shrinking the difference across the resistor, so the current — driven by that difference — falls. Less current, slower charging; slower charging, slower voltage rise. The process throttles itself in exact proportion to how much remains to be done, and that proportionality is the fingerprint of the exponential: in each time constant the capacitor closes 63.2% of whatever gap is left, whether the gap is the whole supply or the last whisper of it.

This is why "fully charged" needs a working definition. Mathematically the curve approaches the supply voltage forever and arrives never; practically, after 5τ the remaining gap is 0.67% — below the tolerance of the components themselves — and engineers declare the job done. The same logic sets discharge expectations: a capacitor bleeding through a resistor keeps 36.8% of its charge after one τ and 0.67% after five, which is why safety discharge resistors are specified to reach a safe voltage within a stated number of time constants, and why a big capacitor can still bite minutes after switch-off if its discharge path is a megohm of good intentions.

63% at t = τ 100% % charged τ 2τ 3τ 4τ 5τ 86% by 2τ · 95% by 3τ · 99.3% by 5τ

How to use

  1. Enter R and pick its unit (Ω, kΩ or MΩ), then enter C and pick its unit (F, mF or µF).
  2. Optionally enter a time t in seconds to find the percentage charge at that moment.
  3. Click "Calculate" for the time constant in seconds and milliseconds, plus the 5τ "fully charged" time.
  4. If you entered t, read the percentage charged and the percentage still to go — they always add to 100.
  5. Designing backwards? Rearrange: R = τ ÷ C or C = τ ÷ R, then round to the nearest standard value and re-check τ with this calculator.

Worked examples

Example 1 — the reference circuit. A 1 kΩ resistor charges a 100 µF capacitor.
τ = RC = 1000 × 100 × 10−6 = 0.1 s.
At t = 0.1 s (exactly one time constant): % charged = (1 − e−1) × 100 = 63.21%.
At t = 0.05 s it is (1 − e−0.5) × 100 = 39.35%, and by t = 5τ = 0.5 s it is over 99% charged.

Example 2 — a one-second heartbeat. A 2.2 kΩ resistor and a 470 µF capacitor: τ = 2200 × 470 × 10−6 = 1.03 s, fully charged (for practical purposes) after 5τ ≈ 5.2 s. This is the scale of LED fade-ins, soft-start ramps and the pause before a relay pulls in — human-scale timing from two unremarkable parts.

Example 3 — the 90% delay. A 100 kΩ resistor and 10 µF capacitor give τ = 100,000 × 10 × 10−6 = 1 s. When does a detector watching for 90% fire? At t = 2.303τ ≈ 2.3 s, because 1 − e−2.303 = 0.90. The magic number 2.303 is ln 10 — every factor-of-ten in the remaining gap costs another 2.303 time constants, for charging and discharging alike.

Example 4 — discharging a flash capacitor. A 100 µF capacitor charged for a camera flash is discharged through 50 Ω for safety: τ = 50 × 100 × 10−6 = 5 ms. After one τ (5 ms) only e−1 = 36.8% of its voltage remains; after 25 ms (5τ) it is down to 0.67% — safe. Discharge is the charging curve read in the mirror, with the same τ.

Example 5 — the milestone table in action. For any circuit, the milestones are fixed: at 2τ a charging capacitor is 1 − e−2 = 86.47% full; at 3τ, 95.02%; at 4τ, 98.17%. Apply them to Example 2's 1.03 s circuit and you can predict its voltage at 2.06 s, 3.09 s and 4.12 s without touching a calculator — the percentages belong to the ratio t ÷ τ, not to the parts.

Example 6 — designing for a 1 ms blip. A debounce network needs τ = 1 ms and a 1 µF capacitor is to hand. R = τ ÷ C = 0.001 ÷ 10−6 = 1000 Ω = 1 kΩ. Check with the calculator: 1 kΩ × 1 µF = 1 ms exactly. Switch contacts bounce for a few milliseconds, so a τ of this size swallows the bounces whole — the entire design was one rearrangement.

RC time constants in real life

555 timers and oscillators. The world's most common timer chip charges a capacitor through resistors and flips its output at fixed fractions of the supply — its timing formulas are τ with thresholds attached. Every blinking LED kit and workshop oscillator is an RC curve being watched by a comparator.

Switch debouncing. Mechanical contacts bounce for milliseconds, generating a burst of false presses. A small RC network (Example 6's scale) smooths the burst into one clean transition, because the capacitor cannot change its voltage as fast as the contacts can chatter.

Power-supply soft start. Slamming a big capacitive load onto a supply draws a destructive inrush. Charging it through a resistor with a τ of tens of milliseconds spreads the surge; a relay or MOSFET then bypasses the resistor once the capacitor is up. τ is the difference between a click and a bang.

Audio filters and tone controls. Every RC low-pass and high-pass filter is a time constant viewed by frequency: signals much faster than 1 ÷ τ are resisted, slower ones pass. The guitar tone knob, the rumble filter and the anti-aliasing filter before every analogue-to-digital converter are chosen with fc = 1 ÷ (2πτ).

Camera flashes and defibrillators. The whine of a charging flash is an RC charge curve being climbed at audible effort; the discharge that fires the tube is the same curve falling through a near-zero resistance, with τ in microseconds. Energy storage is only useful with both halves of the curve designed.

Watchdog and reset delays. Microcontrollers hold themselves in reset until an RC network certifies the supply has been up and stable for a few time constants. The humble power-on reset that starts every gadget politely is, more often than not, one resistor, one capacitor and the number 5τ.

36.8% left at t = τ % remaining (discharge) τ 2τ 3τ 4τ 5τ the mirror curve: same τ, falling

One curve, everywhere: the exponential family

The RC curve is a single member of a family that runs half of science. Radioactive decay is the discharge curve with a half-life instead of a time constant (the conversion is t½ = τ × ln 2 ≈ 0.693τ). A cup of coffee cooling toward room temperature charges — negatively — toward its environment with a thermal time constant. A bouncing ball's energy, a drug concentration in a bloodstream, the pressure in a leaking gas line: all are governed by "rate proportional to what remains", and all trace this page's curve. Learn to think in time constants here, with a resistor and capacitor you can hold, and you own the intuition for all of them: after one τ, about 63% of the journey is done; after five, for any practical purpose, all of it is.

Big R or big C? Choosing the pair in practice

Any τ can be built from many R–C pairs — 1 s is 1 MΩ × 1 µF, 10 kΩ × 100 µF, or 100 Ω × 10,000 µF — and the choice is a real design decision. Large resistances make the timing node feeble: leakage currents through the capacitor and the measuring circuit become rivals to the charging current, and stray signals couple in easily. Large capacitances mean electrolytics, with their wide tolerances, temperature drift and leakage of their own. The comfortable middle — kilohms to hundreds of kilohms, nanofarads to tens of microfarads, film or ceramic dielectrics where precision matters — is where most timing designs live. For very long delays the honest answer is often to abandon RC altogether and count clock cycles digitally; for short, cheap, forgiving delays, one resistor and one capacitor remain unbeatable on price.

Quick reference: the exponential milestones

tCharging: % of finalDischarging: % remaining
0.5τ39.35%60.65%
1τ63.21%36.79%
2τ86.47%13.53%
2.303τ90%10%
3τ95.02%4.98%
4τ98.17%1.83%
5τ99.33%0.67%

Memorise three rows — 1τ, 2.303τ and 5τ — and you can estimate any RC circuit's behaviour at a glance: one time constant to get most of the way, 2.3 to get within a factor of ten, five to be done.

Common mistakes

  • Mixing units before multiplying. τ = RC needs ohms and farads (or the matched pairs kΩ·µF = ms, MΩ·µF = s). Multiplying 1 kΩ by 100 µF as "1 × 100" gives 100 of nothing. Use the calculator's unit selectors, or convert first.
  • Expecting linear charging. A capacitor does not gain equal charge in equal times — it gains 63% of the remaining gap per τ. Designs that assume "half the time, half the charge" misjudge every threshold; at t = τ the charge is 63%, not 50%.
  • Calling it done at 1τ. One time constant is only 63%. Circuits specified to settle — ADC inputs, sample-and-holds, reset lines — usually need 5τ, and precision ones more: each extra τ divides the remaining error by e.
  • Forgetting the discharge path's resistance. τ uses the total resistance the capacitor actually sees. A capacitor discharging through a load and a bleed resistor in parallel sees their parallel combination — a smaller R, a smaller τ, a faster fall than the naive single-resistor figure.
  • Ignoring capacitor tolerance in timing. Electrolytics are commonly ±20%, so a "1 second" timer built on one can honestly run 0.8–1.2 s. Precision timing uses film or ceramic capacitors and 1% resistors — or counts clock cycles instead and skips the analogue uncertainty altogether.

FAQ

What does the time constant actually mean?
τ is the time the capacitor would take to charge fully if it kept charging at its initial rate. In reality the charging slows down, so at t = τ it has reached 63.2% — and it gains another 63.2% of the remaining gap in each further τ.

Why do we say "fully charged" after 5τ?
After 5 time constants the charge is 1 − e−5 = 99.3% of maximum. The last fraction takes forever in theory, so 5τ is the practical "done" point used in electronics.

Does the same τ apply when discharging?
Yes. A discharging capacitor falls to 36.8% of its charge after one τ, and follows the mirror image of the charging curve with the same time constant RC.

Why 63% and not a rounder number?
Because 1 − e−1 = 0.6321. The number is not chosen; it falls out of the exponential with base e. Nature picked e when she made rates proportional to remaining gaps — the 63% is just e's signature at t = τ.

Can τ be negative or zero?
No. R and C are positive quantities, so τ is positive. τ approaching zero means an ideal capacitor connected to an ideal source — infinite current for zero time — which is why real circuits always have some resistance, even if it is only the wiring and the capacitor's own ESR.

What resistance does the capacitor "see" in a complex circuit?
The Thévenin resistance across its terminals with independent sources turned off. In a divider-fed RC, for instance, the capacitor sees the divider's two resistors in parallel. Getting R right is most of practical RC design; the multiplication afterwards is trivial.

Does the supply voltage change τ?
No — τ = RC contains no voltage. A bigger supply charges the capacitor toward a higher target at a proportionally higher initial current, and the percentages at each t ÷ τ are identical. Voltage sets the destination; RC sets the pace.

How does τ relate to filter cut-off frequency?
For a simple RC low-pass filter, fc = 1 ÷ (2πRC) = 1 ÷ (2πτ). Example 1's τ = 0.1 s gives fc ≈ 1.59 Hz. Signals well below fc pass; well above it, the capacitor cannot charge fast enough to follow, and they are smoothed away.

Why do datasheets quote time constants for sensors?
Many sensors — thermistors, photodiodes with their junction capacitance, humidity elements — respond exponentially to a step change, and their τ tells you how long to wait for a trustworthy reading: about 5τ for the full value, or 1τ if 63% is enough to act on.

What happens with two RC stages in a row?
The second stage loads the first, so the combined response is not simply a single exponential with a summed τ — it is slower and S-shaped at the start. Designers buffer stages or use the exact two-pole mathematics; the milestone table on this page applies strictly to a single RC pair.

Michael Chen

Michael Chen

Electronics Specialist

Michael Chen creates and reviews our electronics and circuits calculators at CalcVIP. Every calculator is checked against hand-worked examples before it is published, so the formula, the diagram and the answer all agree.