Magnetic Flux Solver – Solve Φ = BA cos θ for B, A or θ

Use this free Magnetic Flux Solver to rearrange Φ = B × A × cos θ and solve for whichever quantity is missing — the field B, the area A, or the angle θ — instead of always starting from the flux.

Magnetic flux is the accountant's quantity of electromagnetism: it counts how much magnetic field passes through a surface. Picture field lines as rain and the loop as a bucket opening — the flux is the rate at which the bucket catches rain, depending on the rain's strength (B), the bucket's mouth (A), and how squarely the bucket faces the downpour (cos θ). This solver works the relation Φ = BA cos θ in every direction, finding whichever of the four quantities you did not measure from the three you did.

Flux earns its keep through one of the deepest laws in physics: Faraday's law, which says that a changing flux induces a voltage — exactly one volt per weber-per-second in a single turn. Every generator, transformer, induction hob and wireless charger is flux bookkeeping with the numbers filled in. That is why a solver that runs the formula backwards matters: engineers rarely start from flux. They start from a voltage they need, a coil that fits their housing, or a magnet they can buy, and must reason back to the flux, the field or the angle that makes the sums work.

Magnetic Flux Solver — formula and diagram

The cos θ factor deserves respect, because it is where most flux errors live. θ is measured from the surface's normal — the line sticking straight out of the loop's face — not from the face itself. Face-on to the field means θ = 0° and full flux; edge-on means θ = 90° and none, however strong the field or large the loop. Between the two, the flux falls as the cosine, gently at first (a 30° tilt costs only 13%) and then steeply (60° costs half). Getting this angle's definition backwards is the single most common flux mistake, and this page's examples keep it in view.

normal θ B flux counts only the field's component along the normal: B cos θ

Formula

Φ = B × A × cos θ  •  rearranged as B = Φ ÷ (A cos θ), A = Φ ÷ (B cos θ) and θ = cos⁻¹(Φ ÷ BA). θ is measured between the field and the normal to the loop (the line perpendicular to its face), so a loop face-on to the field has θ = 0° and maximum flux.

Two extensions turn the bare formula into engineering. For a coil of N turns the quantity that matters is the flux linkage, N × Φ — each turn catches the same flux and their induced voltages add. And when the field is not uniform, the honest definition is an integral, Φ = ∫ B · dA: the surface is tiled into small patches, each contributing its local B × area × cos θ. The uniform formula on this page is that integral evaluated for the tidy case — which covers most textbook and laboratory work, since magnets are usually designed to be uniform exactly where the coil sits.

SymbolMeaningUnits
Φmagnetic flux through the surfacewebers (Wb)
Bmagnetic field strengthtesla (T)
Aarea of the loop or surfacem²
θangle between B and the surface's normaldegrees (°)
Nturns in a coil — flux linkage is NΦ— (a count)

Flux is a signed, surface-by-surface quantity

Flux carries a sign, fixed by which way you choose the normal to point: field entering the chosen face counts positive, field leaving it negative. The sign is not pedantry — it is what makes Faraday's law give the induced voltage its direction, and it powers one of the prettiest results in physics. Add the flux over a closed surface — a balloon rather than a bucket — and the total is always exactly zero: every field line that enters must leave, because magnetic field lines never end. That statement, ∮ B · dA = 0, is Gauss's law for magnetism, and it is the formal way of saying there are no magnetic monopoles: no isolated north poles exist to serve as sources or sinks of flux.

The same idea, applied to an open surface, explains why only the boundary matters. The flux through any surface spanning a given loop is the same, whether the surface is flat, bulged or crumpled — because the difference between two such surfaces is a closed surface, whose flux is zero. This is why engineers can compute a coil's flux using whichever spanning surface is easiest — usually the flat disc — and why "flux through the loop" is a well-defined phrase even though a loop, strictly, encloses no surface at all.

0°: Φ = BA (max) 30°: 0.866 BA 45°: 0.707 BA 60°: 0.5 BA 90°: 0 flux falls as cos θ — gently at first, then fast

How to use

  1. Pick what you want to find — B, A or θ — and the input boxes relabel themselves to match.
  2. Enter the three values you know: flux in webers, field in tesla, area in square metres, angle in degrees from the normal.
  3. Click "Calculate" to solve for the missing quantity.
  4. If the solver reports no solution for θ, your flux exceeds B × A — the physical maximum. Recheck the units, especially whether the area was converted from cm² (divide by 10,000).

Worked examples

Example 1 — solving for the field. A flux of Φ = 0.002 Wb passes through a loop of area A = 0.04 m² whose normal is tilted at θ = 30° to the field. Find B.
B = Φ ÷ (A cos θ) = 0.002 ÷ (0.04 × cos 30°) = 0.002 ÷ 0.03464 = 0.0577 T = 57.7 mT.
Had the loop been face-on (θ = 0°), the same flux would have needed only B = 0.050 T — tilting the loop wastes part of the field, and this solver tells you exactly how much.

Example 2 — solving for the area. A designer needs a flux of Φ = 0.01 Wb from a magnet giving B = 0.5 T, with the coil face-on (θ = 0°). A = Φ ÷ (B cos θ) = 0.01 ÷ 0.5 = 0.02 m² = 200 cm² — a coil about 16 cm across if circular. Area is flux bought with space, and this is the calculation that sizes search coils and pickup windings.

Example 3 — solving for the angle. A loop of A = 0.02 m² in a field of B = 0.2 T is found to carry a flux of Φ = 0.003 Wb. Since B × A = 0.004 Wb, cos θ = 0.003 ÷ 0.004 = 0.75, so θ = cos⁻¹(0.75) = 41.4°. This is a genuine measurement technique: a fluxmeter and a known field turn a coil into a protractor.

Example 4 — from flux to voltage. A field of B = 0.3 T crosses a coil of A = 0.05 m² at θ = 60°: Φ = 0.3 × 0.05 × 0.5 = 0.0075 Wb per turn. With N = 200 turns the flux linkage is 200 × 0.0075 = 1.5 Wb-turns, and if that flux collapses in 0.01 s, Faraday's law gives an induced EMF of 200 × 0.0075 ÷ 0.01 = 150 V — a healthy spark's worth, from a modest magnet, purely by changing the flux quickly.

Example 5 — the Earth's flux through a door-sized loop. A loop of 1 m² held face-on to the Earth's field (B ≈ 50 µT) catches Φ = 50 × 10⁻⁶ × 1 = 5 × 10⁻⁵ Wb = 50 µWb. Tiny — but spin that loop at 10 revolutions per second and the flux swings sinusoidally, generating an alternating voltage: the principle of the earth inductor compass once used to measure the field's direction.

Example 6 — a tilted search coil. A fluxmeter reports Φ = 0.0012 Wb through a coil of A = 0.03 m² known to sit at θ = 45°. B = 0.0012 ÷ (0.03 × cos 45°) = 0.0012 ÷ 0.02121 = 0.0566 T ≈ 56.6 mT. Note how close this sits to Example 1 despite the different numbers — cos 45° with a larger area nearly reproduces the cos 30° geometry.

Magnetic flux in real life

Generators. A power-station alternator is a flux machine: coils rotate through a field so the flux through them swings between +BA and −BA thousands of times a minute, and the induced voltage is the time-derivative of exactly the quantity this solver handles.

Transformers. The core carries one shared flux; each winding's voltage is its turns count times the flux's rate of change. Core area and peak flux — chosen with the transformer flux formula — decide whether the iron saturates.

Fluxmeters and search coils. To measure an unknown field, technicians flip a calibrated coil in it and integrate the induced voltage: the integral is the flux change, and dividing by the coil's area gives B. Example 3 is this instrument run in reverse.

Induction heating and hobs. An alternating flux driven through a pan's base induces eddy currents that heat it. The flux is deliberately confined and concentrated — area and angle are engineered so Φ threads the pan, not the cook.

Magnetic bearings and levitation. Position sensors in active magnetic bearings watch the flux in small sensing coils; a change in flux betrays a shift of the rotor long before it can be seen, letting the controller correct it.

Geophysics. Magnetotelluric surveys read the Earth's natural flux variations at the surface to infer the conductivity of rock kilometres below — flux as a probe of the deep Earth, on areas of square metres and fields of nanotesla.

N S galvanometer Φ through the coil changes… …and ε = −N × (change in Φ) ÷ (time taken) appears

Flux linkage and Faraday's law: why the weber has a second job

The weber is defined so that a flux changing at one weber per second induces exactly one volt in one turn. Multiply by turns and the statement becomes the working law ε = −N dΦ/dt, the minus sign encoding Lenz's law — the induced voltage drives currents that oppose the change. Every application in the list above is this law wearing different clothes, and it reframes the solver's three modes as three engineering questions: given a voltage and a switching speed, how much flux must change (design the core); given the flux, what area must the coil present (design the winding); given both, how much tilt can the assembly tolerate before the voltage falls short (design the mounting). Example 4's 150 V from a collapsing 0.0075 Wb shows the leverage of speed: the same flux changed a hundred times more slowly would give 1.5 V. Flux is the stored quantity; its rate of change is the spent one.

Flux per pole: how machine designers actually talk

Inside the electrical-machine industry this solver's quantity has a working name — flux per pole — and a working measurement. A designer specifies a motor or generator by the flux each pole must carry, because the voltage of every coil under that pole follows from it through Faraday's law; frame sizes, core stacks and winding counts are then chosen to deliver that flux at a sane flux density. The measurement is equally direct and is the flux-solver in laboratory clothes: a search coil wound around the pole is connected to a fluxmeter and flipped or withdrawn, and the instrument integrates the induced voltage to display the flux change. Flip the Example 4 coil (Φ = 0.0075 Wb per turn) right over and the change is twice the flux, 0.015 Wb per turn — 3.0 Wb-turns of linkage for its 200 turns — a number the fluxmeter reads directly. Between design table and test bench, then, flux is not an abstraction: it is specified, budgeted and measured, in webers, every working day.

Quick reference: flux through a 0.01 m² loop in a 0.1 T field

θ (from normal)cos θFlux Φ
0°1.0001.00 × 10⁻³ Wb
30°0.8668.66 × 10⁻⁴ Wb
45°0.7077.07 × 10⁻⁴ Wb
60°0.5005.00 × 10⁻⁴ Wb
90°00 Wb

The table's lesson is asymmetry: alignment is forgiving near 0° (a 30° misalignment costs only 13% of the flux) and punishing near 90°, where small angular errors swing the flux wildly in relative terms. Mount coils square, or measure the tilt and correct with this solver.

Common mistakes

  • Measuring θ from the face. The formula's θ is from the normal. If your protractor reads the angle between the field and the loop's plane, subtract it from 90° before entering — or equivalently use sin of the face angle.
  • Leaving the area in cm². Areas must be in m²: divide cm² by 10,000. This is the error behind most "impossible" solver results, including fluxes larger than BA.
  • Forgetting the turns. Φ is per turn. A 200-turn coil in the Example 4 field links 1.5 Wb-turns, and its induced voltage is 200 times the single-turn figure — omitting N understates every generator calculation.
  • Assuming B is uniform when it is not. Near a magnet's pole edge the field can halve across a coil's width. The formula then gives only a rough average; the integral form, or a smaller coil, is the honest fix.
  • Expecting a steady flux to induce a steady voltage. Only change induces. A loop can sit in an enormous flux forever and generate nothing — the fact that makes transformers AC-only devices.

FAQ

Why is θ measured from the normal and not from the loop's face?
By convention flux counts the field component passing through the surface, which is the component along the normal. If your angle is measured from the face instead, use 90° minus that angle here.

What if the flux is larger than B × A?
That is impossible — BA is the maximum flux, reached at θ = 0°. If you ask for θ with Φ > BA, the solver reports that no such angle exists, which usually means a unit slip (for example cm² not converted to m²).

What is a weber in plain terms?
One weber is one tesla flowing through one square metre. A changing flux of 1 Wb per second induces exactly 1 volt in a single-turn loop — the link between flux and Faraday's law.

Can flux be negative?
Yes — the sign records direction relative to the chosen normal. Reverse the loop (or the field) and the flux changes sign. The magnitude is what this solver finds; the sign follows your convention for which face is "front".

What is flux linkage, and when do I need it?
Flux linkage is N × Φ for an N-turn coil — the total flux threaded by all turns together. You need it whenever a voltage is involved, because each turn contributes its own induced EMF and they add.

Does the loop's shape affect the flux?
Only through its area. A circular, square or irregular loop of the same area in the same uniform field catches identical flux — which is why search coils are specified by their area-turns product alone.

How is flux actually measured?
With a fluxmeter: a search coil is flipped or withdrawn from the field, the induced voltage is integrated electronically, and the integral equals the flux change. It is Faraday's law used as an instrument — the standard way fields inside machines are mapped.

Why does the flux through a closed surface always vanish?
Because field lines have no ends — every line entering a closed surface leaves it, so the net count is zero. This is Gauss's law for magnetism, equivalent to the non-existence of magnetic monopoles.

What is the flux of the Earth's field through my house?
Vertically, very little: the field's vertical component in mid-latitudes is roughly 40 µT, so a 100 m² roof catches about 4 × 10⁻³ Wb through its floor plan — real, but utterly steady, so it induces nothing.

How does flux relate to inductance?
Directly: a coil's flux linkage per amp is its inductance, L = NΦ/I. Measure the flux a known current produces through its own coil and you have measured L — the bridge between this page and the inductance calculators.

Thomas Becker

Thomas Becker

Physics Writer · Electricity & Magnetism

Thomas Becker creates and reviews our magnetism and electrostatics calculators at CalcVIP. Every calculator is checked against hand-worked examples before it is published, so the formula, the diagram and the answer all agree.

View full profile & all calculators by Becker →