Solar Panel Output Calculator – Daily & Monthly kWh from Panels and Sun Hours

Use this free Solar Panel Output Calculator to estimate how much electricity a solar panel system produces per day and per month. Enter the panel wattage, number of panels, peak sun hours for your area and a derate factor for real-world losses.

A solar panel's wattage is a laboratory promise: the power it produces under standard test conditions — a noon sun of exactly 1,000 W/m² falling squarely on a cool panel. Real roofs offer slanted light, hot panels, dusty glass and an inverter between the panels and the kettle. This calculator bridges the laboratory and the roof with the standard estimator used across the industry: multiply the system's rated watts by the location's peak sun hours and by a derate factor that honestly discounts the losses, and you get the energy the system will actually deliver per day and per month, in kilowatt-hours — the unit on your electricity bill.

Peak sun hours are the concept that makes the estimate work, and they are widely misunderstood: they are not the hours of daylight. A peak sun hour is an accounting unit — one hour's worth of full-strength, 1,000 W/m² sunshine. A bright location may collect ten hours of daylight whose total energy equals only five hours at full strength, because morning and evening sun arrives weakened and slanted. Compressing the whole day's sunshine into its full-strength equivalent is what lets a single multiplication replace a day of integration, and location tables (3 hours in a cloudy northern winter, 6–7 in a desert) carry the climate inside one number.

Solar Panel Output Calculator — formula and diagram

The derate factor, conventionally about 0.85, is the estimate's conscience. Panels run hot and lose efficiency, inverters skim a few percent, cables and dust take their cut; pretending otherwise inflates every projection by nearly a fifth. The concept section below itemises the 0.85 into its typical components, and the worked examples range from a single panel to a desert array, so the arithmetic can be calibrated against any system you are planning, auditing or arguing about.

10 × 400 W = 4 kW system × 5 peak sun hours × 0.85 derate = 17 kWh per day

Formula

Daily energy (kWh) = Panel watts × Number of panels × Peak sun hours × Derate ÷ 1,000  •  Monthly = Daily × 30  •  Yearly ≈ Daily × 365

Each factor earns its place. Panel watts × number of panels is the system's nameplate capacity in watts — its output under perfect test sunshine. Multiplying by peak sun hours converts that power into the day's energy at full-strength-equivalent exposure, and dividing by 1,000 moves watts to kilowatts so the answer lands in kWh. The derate then taxes the ideal figure for the real world. Note what the formula does not contain: panel area and efficiency separately (they are already baked into the rated watts), battery behaviour (this is generation, not storage), and any hour-by-hour detail — the whole method is a deliberate, well-tested compression of a messy day into four numbers. Rearranged, it also answers the design question: panels needed = target daily kWh × 1,000 ÷ (panel watts × sun hours × derate), as Example 6 demonstrates.

SymbolMeaningUnits
Wprated power of one panel (nameplate, at STC)W
Nnumber of panels—
Hpeak sun hours for the location (daily average)h
Dderate factor — real-world losses (typically 0.85)0–1
Eenergy producedkWh

Peak sun hours and the anatomy of the 0.85

A location's peak sun hours are measured by adding up the day's actual solar energy and dividing by 1,000 W/m². If a roof receives 5,000 Wh/m² across a day — weak at dawn, strong at noon, weak again at dusk — it has had 5 peak sun hours, and a correctly tilted panel is credited with 5 hours at its nameplate rate. The bell curve of the day is thereby folded into a rectangle of equal area, which is all the formula needs. Seasonal swing rides along: the same roof might average 6.5 peak hours in June and 2.5 in December, so yearly estimates should use the annual average (or be built month by month) rather than the flattering summer figure an installer quotes first.

The derate factor decomposes into a chain of small multiplications, each with a typical size: the inverter converts DC to AC at about 96% (× 0.96), hot panels underperform their cool-lab rating by roughly 5% on average (× 0.95), dust and bird-lime cost about 3% (× 0.97), and wiring, mismatch between panels and connections take about 4% (× 0.96). Multiplied through: 0.96 × 0.95 × 0.97 × 0.96 ≈ 0.85. A shaded, dirty or badly angled system deserves 0.75 or lower; a cool, clean, perfectly tilted one might justify 0.9. The number is not fudge — it is an itemised receipt, and adjusting its line items for your roof is the difference between an estimate and a guess.

the same energy as 5 hours at full strength dawn noon dusk a day's sunshine, folded flat

How to use

  1. Enter the rated watts of one panel, exactly as printed on its label or datasheet (modern residential panels are typically 350–450 W).
  2. Enter the number of panels in the system.
  3. Enter your location's average peak sun hours — from a solar map or PVGIS-style table for your region; use the yearly average for yearly questions, or a specific month's figure for monthly ones.
  4. Keep the derate at 0.85 unless your circumstances argue otherwise (heavy shade or soiling: lower it; cool climate, perfect tilt, premium inverter: nudge it up). Click "Calculate Output" for daily, monthly and yearly energy.

Worked examples

Example 1 — the reference rooftop. 10 panels × 400 W, 5 peak sun hours, derate 0.85: daily output = 400 × 10 × 5 × 0.85 ÷ 1,000 = 17 kWh per day, about 510 kWh per month and roughly 6,205 kWh per year. For scale, that daily figure covers a typical efficient household's entire consumption — the reason 4 kW rooftops are the industry's default recommendation.

Example 2 — one panel. A single 400 W panel under the same sun: 400 × 1 × 5 × 0.85 ÷ 1,000 = 1.7 kWh per day. Enough for lighting, devices and a fridge's daily ration in an off-grid cabin — the arithmetic that sizes balcony and camper-van systems.

Example 3 — the small cabin system. 4 panels × 300 W, 4 peak sun hours, derate 0.8: 300 × 4 × 4 × 0.8 ÷ 1,000 = 3.84 kWh per day, about 115.2 kWh per month. Modest — but matched against a cabin's frugal loads (LED lights, a small fridge, a laptop) it is a workable budget, and the derate of 0.8 honestly prices the older equipment.

Example 4 — the desert array. 20 panels × 450 W under 6.5 peak sun hours at 0.85: 450 × 20 × 6.5 × 0.85 ÷ 1,000 = 49.73 kWh per day, about 1,491.75 kWh per month. Sunshine is a resource with geography: the same hardware earns roughly triple in a desert what it earns under northern clouds (compare Example 5).

Example 5 — the cloudy north. 8 panels × 350 W, only 3 peak sun hours, derate 0.85: 350 × 8 × 3 × 0.85 ÷ 1,000 = 7.14 kWh per day. Solar still pays in such climates — panels are cheap and electricity is dear — but the sizing must start from 3, not from the 5–6 of sunnier brochures.

Example 6 — how many panels for 30 kWh a day? Rearranged: panels = 30,000 ÷ (400 × 5 × 0.85) = 30,000 ÷ 1,700 ≈ 17.65 — so 18 panels, which deliver 400 × 18 × 5 × 0.85 ÷ 1,000 = 30.6 kWh per day, just clearing the target. Always round panel counts up; the 0.65 of a panel cannot be bought, and the small surplus is the system's insurance against dull weeks.

Solar output in real life

Matching a system to a bill. Read last year's kWh from your electricity bills, divide by 365 for the daily target, and Example 6's rearrangement sizes the array. It is the first calculation every reputable installer performs — and the one that exposes disreputable ones quoting panel counts without asking about consumption.

Off-grid design. Cabins, boats and RVs live or die by the daily figure: loads are budgeted in kWh, the array must cover them in the worst month planned for, and Example 3's honest derate is the difference between lights that work in November and lights that do not.

Solar farms. Scale Example 4 by a thousand: 1 MW of panels under 5 peak sun hours at 0.85 yields about 4,250 kWh per day. Utility projects are this formula wearing a suit — with tracking mounts and bifacial panels arguing the derate and sun-hours upward line by line.

Capacity factor. Example 1's 4 kW system making 17 kWh in 24 hours runs at a capacity factor of 17 ÷ (4 × 24) ≈ 17.7% — the standard yardstick for comparing solar with wind (typically 25–40%) and other generators, all from this page's arithmetic.

Water pumping and agriculture. A solar pump's daily water delivery is set by daily energy: farmers size arrays from crop water needs backwards through the pump's efficiency to a kWh target, then through this calculator to a panel count.

Payback estimates. Multiply the yearly kWh by your electricity price and you have the annual saving the sales pitch is built on — 6,205 kWh at any tariff is a concrete number to set against the installation quote, with the derate already keeping it honest.

1.7 8.5 17 49.7 1 panel 5 panels 10 panels 20 × 450 W, desert sun daily kWh

What the estimate leaves out — deliberately

Three real-world wrinkles sit outside this formula, and knowing them marks the boundary of its honesty. Seasonality: a single sun-hours figure averages the year; systems sized on the annual average run a surplus in summer and a deficit in winter, which grid connection absorbs silently but off-grid batteries cannot. Orientation: peak-sun-hour tables assume a well-tilted, equator-facing array; east- and west-facing roofs harvest perhaps 15–20% less, which belongs in a lowered sun-hours figure or a harsher derate. Degradation: panels fade slowly, roughly half a percent of output per year, so a 20-year projection should taper the daily figure accordingly — a 10% lifetime discount is a fair planning allowance. None of these rescue a bad estimate or ruin a good one; they are the second decimal of solar planning, and the calculator's four inputs remain the first.

Heat: the silent line item

Of all the derate's components, temperature is the one newcomers find hardest to believe — the sunniest hour is not the most productive per unit of light, because panels are semiconductors and semiconductors dislike heat. A typical crystalline panel loses roughly 0.4% of its power for every degree Celsius its cells run above the 25 °C laboratory standard. On a still summer afternoon, cells easily reach 60 °C even in a temperate climate: 35 degrees of excess at 0.4% per degree is a 14% penalty, applied at exactly the moment the sunshine is strongest. This is why spring and autumn often produce a system's best instantaneous power, why ventilated mounting (an air gap behind the panels) measurably outperforms flush mounting, and why desert installations — for all their peerless sun hours — budget a lower derate than the raw sunshine suggests. When you adjust this calculator's derate for a hot climate, this paragraph is the adjustment: the laboratory promise is made at 25 °C, and your roof in August is not a laboratory.

A sanity check for installers' promises

The formula doubles as a lie detector for quotations. Suppose an installer promises "about 20 kWh a day" from a 4 kW system in a location with 5 peak sun hours. Run the claim backwards: 20 kWh from 4 kW over 5 peak hours implies a derate of exactly 1.0 — a system with no inverter loss, no heat penalty, no dust, ever. The honest figure from this calculator is 17 kWh, and the 3 kWh gap is the salesman's margin of optimism, worth real money across a 20-year contract. Any quote can be audited this way in under a minute: divide the promised daily energy by (system kW × local peak sun hours) and inspect the implied derate. Between 0.8 and 0.9, the quote is engineering; above 0.95, it is literature.

Quick reference: daily output of 400 W panels at 5 peak sun hours, derate 0.85

PanelsSystem sizeDaily outputMonthly output
10.4 kW1.7 kWh51 kWh
52 kW8.5 kWh255 kWh
104 kW17 kWh510 kWh
208 kW34 kWh1,020 kWh

The table scales linearly in every direction — double the panels or the sun hours and the output doubles — which makes it a pocket estimator: find your row, adjust for your climate's sun hours by proportion, and you have a defensible first figure for any rooftop conversation.

Common mistakes

  • Using daylight hours instead of peak sun hours. Ten hours of daylight might hold only five peak sun hours of energy. Doubling the hours doubles the promised output — the most common and most expensive error in amateur solar estimates.
  • Skipping the derate. Setting D = 1 overstates output by about 18% (1 ÷ 0.85 ≈ 1.18). Systems sized on underrated figures miss their targets every single day, not just on bad ones.
  • Forgetting the ÷ 1,000. Watts × hours gives watt-hours. Reporting Example 1 as "17,000 kWh" is a three-orders-of-magnitude slip that the calculator prevents and hand calculations invite.
  • Treating monthly output as daily × 30 in every season. The calculator's monthly figure inherits whatever sun hours you entered. Enter June's hours and the "month" is June; winter needs its own, smaller input.
  • Confusing power with energy. A 4 kW system does not make "4 kWh per hour all day" — it makes 4 kWh in one peak hour, less in others, none at night. kW is the rate, kWh the harvest; the sun-hours concept exists to convert one to the other honestly.

FAQ

What are peak sun hours?
Not the same as daylight hours. One peak sun hour means one hour of sunshine at full test strength (1000 W/m²). A location with 10 daylight hours might average only 5 peak sun hours.

Why the derate factor?
Panels rarely deliver their label rating: heat lowers their efficiency, the inverter wastes a few percent, and dust and cables lose a little more. Multiplying by about 0.85 gives a realistic estimate.

Will output be the same every day?
No — this is an average. Cloudy days produce much less and clear summer days more. Use yearly average sun hours for a fair yearly estimate.

How many panels does an average house need?
Work from consumption: a household using 30 kWh a day in a 5-peak-hour location needs about 18 × 400 W panels (Example 6); a frugal 15 kWh household needs about 9. There is no universal count — the bill decides, the climate adjusts, the formula arbitrates.

Do panels produce anything on a cloudy day?
Yes — typically 10–25% of their clear-sky output, because clouds scatter rather than block sunlight, and panels harvest diffuse light too. The peak-sun-hours average already has cloudy days folded into it, which is why the estimate holds up over a month despite useless individual days.

What are standard test conditions (STC)?
The laboratory recipe behind the nameplate watts: irradiance of 1,000 W/m², panel temperature of 25 °C, and a standard spectrum. Real panels run at 45–65 °C in summer sun — the temperature gap alone is most of the derate's largest line item.

Which way should panels face?
Towards the equator — south in the northern hemisphere, north in the southern — tilted at roughly the location's latitude. Deviations cost less than people fear: a southeast or southwest roof typically loses only a few percent against the ideal.

Do solar panels degrade over time?
Yes, slowly — around 0.5% of output per year for quality modern panels, with warranties commonly guaranteeing about 85–90% of nameplate output after 25 years. Long-term savings projections should taper the daily figure accordingly.

How big a battery would store Example 1's daily output?
The full 17 kWh would need a very large (and expensive) battery bank; most homes store only the evening's share — 5–10 kWh — and export the rest. Storage sizing starts from when you use energy, not just how much the array makes, which is why this calculator deliberately stops at generation.

Why does the calculator cap the derate at 1?
Because a derate above 1 would claim the system beats its own laboratory rating in the real world — possible for a few cold, bright, high-altitude minutes, but never as a planning average. If an estimate needs D > 1 to make sense, one of the other inputs is wrong.

Priya Sharma

Priya Sharma

Physics Editor · Energy & Gravity

Priya Sharma creates and reviews our energy, work, power and gravitation calculators at CalcVIP. Every calculator is checked against hand-worked examples before it is published, so the formula, the diagram and the answer all agree.

View full profile & all calculators by Sharma →